HVCRC CABLES (High Voltage Composite Reinforced Conductors)
HVCRC CABLES (High Voltage Composite Reinforced Conductors)
High-conductivity aluminum conductors made in trapezoidal wires, with a hybrid carbon and glass core that allows operation at high temperatures and low SAG (HTLS).
Read moreAmsterdam - Dove (370 - 47 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: AMSTERDAM / DOVE
- Aluminium cross-section: 369 mm²
- Cross-section of the cores: 47.2 mm²
- Conductor cross-section: 416.2 mm²
- Core diameter: 7.8 mm
- Number of aluminium wires: 18
- Conductor diameter: 23.55 mm
- Nominal outer diameter: 23.55 mm
- Approximate weight: 1107 kg/km
- Max. DC resistance of the conductor at 20°C: 0.077 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.079 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.094 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.126 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.132 Ohm/km
- Inductive reactance: 0.217 Ohm/km
- Capacitive reactance: 0.186 MOhm.km
- Ampacity 180°C: 1459 A
- Ampacity 200°C: 1539 A
- Minimum Tensile Strength Conductor: 128.0 kN
- Nominal Tensile Strength Core: 105.8 kN
Brussels - Grosebeak (430 - 52 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: BRUSSELS / GROSBEAK
- Aluminium cross-section: 421.7 mm²
- Cross-section of the cores: 51.9 mm²
- Conductor cross-section: 473.6 mm²
- Core diameter: 8.1 mm
- Number of aluminium wires: 20
- Conductor diameter: 25.13 mm
- Nominal outer diameter: 25.13 mm
- Approximate weight: 1262 kg/km
- Max. DC resistance of the conductor at 20°C: 0.068 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.069 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.082 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.111 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.116 Ohm/km
- Inductive reactance: 0.213 Ohm/km
- Capacitive reactance: 0.183 MOhm.km
- Ampacity 180°C: 1592 A
- Ampacity 200°C: 1680 A
- Minimum Tensile Strength Conductor: 141.8 kN
- Nominal Tensile Strength Core: 116.5 kN
Casablanca - Laredo (280 - 40 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: CASABLANCA / LAREDO
- Aluminium cross-section: 275.5 mm²
- Cross-section of the cores: 39.7 mm²
- Conductor cross-section: 315.2 mm²
- Core diameter: 7.1 mm
- Number of aluminium wires: 16
- Conductor diameter: 20.51 mm
- Nominal outer diameter: 20.51 mm
- Approximate weight: 835.5 kg/km
- Max. DC resistance of the conductor at 20°C: 0.104 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.104 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.125 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.168 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.177 Ohm/km
- Inductive reactance: 0.226 Ohm/km
- Capacitive reactance: 0.194 MOhm.km
- Ampacity 180°C: 1207 A
- Ampacity 200°C: 1273 A
- Minimum Tensile Strength Conductor: 105.6 kN
- Nominal Tensile Strength Core: 89.1 kN
Copenhagen - Linnet (230 - 28 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: COPENHAGEN / LINNET
- Aluminium cross-section: 221.3 mm²
- Cross-section of the cores: 28 mm²
- Conductor cross-section: 249.3 mm²
- Core diameter: 5.9 mm
- Number of aluminium wires: 16
- Conductor diameter: 18.29 mm
- Nominal outer diameter: 18.29 mm
- Approximate weight: 663.8 kg/km
- Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.13 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.155 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.209 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.22 Ohm/km
- Inductive reactance: 0.233 Ohm/km
- Capacitive reactance: 0.201 MOhm.km
- Ampacity 180°C: 1044 A
- Ampacity 200°C: 1100 A
- Minimum Tensile Strength Conductor: 73.1 kN
- Nominal Tensile Strength Core: 59.8 kN
Dublin - Drake (530 - 71 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: DUBLIN / DRAKE
- Aluminium cross-section: 524.8 mm²
- Cross-section of the cores: 71.3 mm²
- Conductor cross-section: 596.1 mm²
- Core diameter: 9.5 mm
- Number of aluminium wires: 22
- Conductor diameter: 28.17 mm
- Nominal outer diameter: 28.17 mm
- Approximate weight: 1583 kg/km
- Max. DC resistance of the conductor at 20°C: 0.054 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.056 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.067 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.089 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.093 Ohm/km
- Inductive reactance: 0.206 Ohm/km
- Capacitive reactance: 0.176 MOhm.km
- Ampacity 180°C: 1841 A
- Ampacity 200°C: 1945 A
- Minimum Tensile Strength Conductor: 191.5 kN
- Nominal Tensile Strength Core: 160.1 kN
Glasgow - Waco (240 - 47 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: GLASGOW / WACO
- Aluminium cross-section: 238.2 mm²
- Cross-section of the cores: 47.2 mm²
- Conductor cross-section: 285.4 mm²
- Core diameter: 7.8 mm
- Number of aluminium wires: 18
- Conductor diameter: 19.55 mm
- Nominal outer diameter: 19.55 mm
- Approximate weight: 746.3 kg/km
- Max. DC resistance of the conductor at 20°C: 0.12 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.121 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.145 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.195 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.204 Ohm/km
- Inductive reactance: 0.228 Ohm/km
- Capacitive reactance: 0.197 MOhm.km
- Ampacity 180°C: 1106 A
- Ampacity 200°C: 1065 A
- Minimum Tensile Strength Conductor: 120.1 kN
- Nominal Tensile Strength Core: 105.8 kN
Helsinki - Pasadena (160 - 28 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: HELSINKI / PASADENA
- Aluminium cross-section: 152.5 mm²
- Cross-section of the cores: 28 mm²
- Conductor cross-section: 180.5 mm²
- Core diameter: 5.9 mm
- Number of aluminium wires: 18
- Conductor diameter: 15.65 mm
- Nominal outer diameter: 15.65 mm
- Approximate weight: 473.8 kg/km
- Max. DC resistance of the conductor at 20°C: 0.187 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.188 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.225 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.303 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.318 Ohm/km
- Inductive reactance: 0.242 Ohm/km
- Capacitive reactance: 0.21 MOhm.km
- Ampacity 180°C: 826 A
- Ampacity 200°C: 869 A
- Minimum Tensile Strength Conductor: 69.0 kN
- Nominal Tensile Strength Core: 59.8 kN
Lisbon - Hawk (320 - 40 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: LISBON / HAWK
- Aluminium cross-section: 316.7 mm²
- Cross-section of the cores: 39.7 mm²
- Conductor cross-section: 356.4 mm²
- Core diameter: 7.1 mm
- Number of aluminium wires: 16
- Conductor diameter: 21.79 mm
- Nominal outer diameter: 21.79 mm
- Approximate weight: 949.5 kg/km
- Max. DC resistance of the conductor at 20°C: 0.09 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.091 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.109 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.147 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.154 Ohm/km
- Inductive reactance: 0.222 Ohm/km
- Capacitive reactance: 0.191 MOhm.km
- Ampacity 180°C: 1319 A
- Ampacity 200°C: 1391 A
- Minimum Tensile Strength Conductor: 108.1 kN
- Nominal Tensile Strength Core: 89.1 kN
Oslo - Irving (320 - 60 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: OSLO / IRVING
- Aluminium cross-section: 315.2 mm²
- Cross-section of the cores: 60.3 mm²
- Conductor cross-section: 375.5 mm²
- Core diameter: 8.8 mm
- Number of aluminium wires: 20
- Conductor diameter: 22.4 mm
- Nominal outer diameter: 22.4 mm
- Approximate weight: 983.5 kg/km
- Max. DC resistance of the conductor at 20°C: 0.091 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.092 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.11 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.147 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.155 Ohm/km
- Inductive reactance: 0.22 Ohm/km
- Capacitive reactance: 0.189 MOhm.km
- Ampacity 180°C: 1327 A
- Ampacity 200°C: 1400 A
- Minimum Tensile Strength Conductor: 154.1 kN
- Nominal Tensile Strength Core: 135.2 kN
Reykjavik - Oriole (230 - 40 mm2)
Nexans ref.
- Packaging: Drum
- Type of cable: REYKJAVIK / ORIOLE
- Aluminium cross-section: 223.1 mm²
- Cross-section of the cores: 39.7 mm²
- Conductor cross-section: 262.8 mm²
- Core diameter: 7.1 mm
- Number of aluminium wires: 20
- Conductor diameter: 18.82 mm
- Nominal outer diameter: 18.82 mm
- Approximate weight: 690.8 kg/km
- Max. DC resistance of the conductor at 20°C: 0.128 Ohm/km
- Max. Electrical Resistance. AC 50Hz 25°C: 0.129 Ohm/km
- Max. Electrical Resistance AC 50Hz 75°C : 0.154 Ohm/km
- Max. Electrical Resistance AC 50Hz 180°C : 0.208 Ohm/km
- Max. Electrical Resistance AC 50Hz 200°C : 0.218 Ohm/km
- Inductive reactance: 0.231 Ohm/km
- Capacitive reactance: 0.199 MOhm.km
- Ampacity 180°C: 1058 A
- Ampacity 200°C: 1114 A
- Minimum Tensile Strength Conductor: 102.5 kN
- Nominal Tensile Strength Core: 89.1 kN
Description
Description
Application
HVCRC CENTELSA by Nexans cables are designed to improve the current capacity of the line, reduce sag and electrical losses and are used in overhead lines for the transmission of electrical energy. Additionally, they are an excellent alternative for transmission line repowering projects.
Construction
Conductor made of trapezoidal wires of high-conductivity annealed aluminum alloy 1350-O, stranded on a carbon and glass fiber core embedded in a high-temperature thermoset resin.
Reference Standards
- ASTM B987
- ASTM B857
- IEC 62219
Certificate
RETIE N°06613
Temperature
- 180°C, Continous operating.
- 200°C, Emergency by 8760 Hours.
Packaging
Wooden Reels.
Ampacity Conditions
Current Capacity at continous operating temperature of 180°C and 200 °C in emergency, calculated according to IEEE Standard 738-2012 under the following conditions:
- Wind 2 ft/s (0.61 m/s) with an angle of 90°.
- Emissivity Coefficient 0.6.
- Solar Absorption Coefficient 0.5.
- Ambient temperature 25°C.
- Solar radiation 93 W/ft2 (1000 W/m2).
- System Frecuency 50 Hz.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania