SELF SUPPORTED MULTIPLEX CABLES (Insulated ACSR Neutral)
SELF SUPPORTED MULTIPLEX CABLES (Insulated ACSR Neutral)
Phase conductors in Aluminum 1350 H-19 (AAC), concentric stranded. Insulation in cross-linked polyethylene XLPE, phase conductors twisted together on an insulated ACSR messenger neutral.
Read more3x4+4 AWG
Nexans ref. 213139
- Conductor cross-section: 21.2 mm²
- Number of cores: 4
- Phase Conductor Conductor cross-section (AWG): 4 AWG
- Nominal insulation thickness: 1.14 mm
- Neutral Conductor cross-section (AWG): 4 AWG
- Insulation thickness of neutral conductor: 0.76 mm
- Approximate weight: 360.61 kg/km
- Nominal outer diameter: 21.39 mm
- Ampacity: 91.0 A
- Max. DC resistance of the conductor at 20°C: 1.387 Ohm/km
- Rated breaking load: 844 kgf
2x4+4 AWG
Nexans ref. 209801
- Conductor cross-section: 21.2 mm²
- Number of cores: 3
- Phase Conductor Conductor cross-section (AWG): 4 AWG
- Nominal insulation thickness: 1.14 mm
- Neutral Conductor cross-section (AWG): 4 AWG
- Insulation thickness of neutral conductor: 0.76 mm
- Approximate weight: 276.93 kg/km
- Nominal outer diameter: 16.87 mm
- Ampacity: 91.0 A
- Max. DC resistance of the conductor at 20°C: 1.387 Ohm/km
- Rated breaking load: 844 kgf
2x2+2 AWG
Nexans ref. 211533
- Conductor cross-section: 33.6 mm²
- Number of cores: 3
- Phase Conductor Conductor cross-section (AWG): 2 AWG
- Nominal insulation thickness: 1.14 mm
- Neutral Conductor cross-section (AWG): 2 AWG
- Insulation thickness of neutral conductor: 1.14 mm
- Approximate weight: 428.31 kg/km
- Nominal outer diameter: 20.87 mm
- Ampacity: 123.0 A
- Max. DC resistance of the conductor at 20°C: 0.874 Ohm/km
- Rated breaking load: 1294 kgf
3x2+2 AWG
Nexans ref. 211671
- Conductor cross-section: 33.6 mm²
- Number of cores: 4
- Phase Conductor Conductor cross-section (AWG): 2 AWG
- Nominal insulation thickness: 1.14 mm
- Neutral Conductor cross-section (AWG): 2 AWG
- Insulation thickness of neutral conductor: 1.14 mm
- Approximate weight: 552.59 kg/km
- Nominal outer diameter: 25.62 mm
- Ampacity: 123.0 A
- Max. DC resistance of the conductor at 20°C: 0.874 Ohm/km
- Rated breaking load: 1294 kgf
1x2+2 AWG
Nexans ref. 211672
- Conductor cross-section: 33.6 mm²
- Number of cores: 2
- Phase Conductor Conductor cross-section (AWG): 2 AWG
- Nominal insulation thickness: 1.14 mm
- Neutral Conductor cross-section (AWG): 2 AWG
- Insulation thickness of neutral conductor: 1.14 mm
- Approximate weight: 304.02 kg/km
- Nominal outer diameter: 19.59 mm
- Ampacity: 123.0 A
- Max. DC resistance of the conductor at 20°C: 0.874 Ohm/km
- Rated breaking load: 1294 kgf
1x1/0+1/0 AWG
Nexans ref. 213069
- Conductor cross-section: 53.5 mm²
- Number of cores: 2
- Phase Conductor Conductor cross-section (AWG): 1/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 1/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 487.14 kg/km
- Nominal outer diameter: 24.95 mm
- Ampacity: 167.0 A
- Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km
- Rated breaking load: 1988 kgf
2x1/0+1/0 AWG
Nexans ref. 200144
- Conductor cross-section: 53.5 mm²
- Number of cores: 3
- Phase Conductor Conductor cross-section (AWG): 1/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 1/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 685.25 kg/km
- Nominal outer diameter: 26.58 mm
- Ampacity: 167.0 A
- Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km
- Rated breaking load: 1988 kgf
3x1/0+1/0 AWG
Nexans ref. 211534
- Conductor cross-section: 53.5 mm²
- Number of cores: 4
- Phase Conductor Conductor cross-section (AWG): 1/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 1/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 883.37 kg/km
- Nominal outer diameter: 32.58 mm
- Ampacity: 167.0 A
- Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km
- Rated breaking load: 1988 kgf
2x2/0+2/0 AWG
Nexans ref. 212068
- Conductor cross-section: 67.4 mm²
- Number of cores: 3
- Phase Conductor Conductor cross-section (AWG): 2/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 2/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 840.32 kg/km
- Nominal outer diameter: 29.02 mm
- Ampacity: 193.0 A
- Max. DC resistance of the conductor at 20°C: 0.437 Ohm/km
- Rated breaking load: 2406 kgf
3x2/0+2/0 AWG
Nexans ref. 200182
- Conductor cross-section: 67.4 mm²
- Number of cores: 4
- Phase Conductor Conductor cross-section (AWG): 2/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 2/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 1082.61 kg/km
- Nominal outer diameter: 35.53 mm
- Ampacity: 193.0 A
- Max. DC resistance of the conductor at 20°C: 0.437 Ohm/km
- Rated breaking load: 2406 kgf
2x4/0+4/0 AWG
Nexans ref. 200157
- Conductor cross-section: 107 mm²
- Number of cores: 3
- Phase Conductor Conductor cross-section (AWG): 4/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 4/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 1275.64 kg/km
- Nominal outer diameter: 34.84 mm
- Ampacity: 262.0 A
- Max. DC resistance of the conductor at 20°C: 0.274 Ohm/km
- Rated breaking load: 3790 kgf
3x4/0+4/0 AWG
Nexans ref. 200187
- Conductor cross-section: 107 mm²
- Number of cores: 4
- Phase Conductor Conductor cross-section (AWG): 4/0 AWG
- Nominal insulation thickness: 1.52 mm
- Neutral Conductor cross-section (AWG): 4/0 AWG
- Insulation thickness of neutral conductor: 1.52 mm
- Approximate weight: 1641.67 kg/km
- Nominal outer diameter: 42.54 mm
- Ampacity: 262.0 A
- Max. DC resistance of the conductor at 20°C: 0.274 Ohm/km
- Rated breaking load: 3790 kgf
Description
Description
Standards
-
ProductASTM B 232; ICEA S-76-474
-
NationalNTC 309; NTC 5346
Applications
SELF SUPPORTED MULTIPLEX CABLES Centelsa by Nexans are used in aerial secondary distribution systems, in public lighting or in temporary construction installations, connection with the transformer to the point of derivation for the user or connection with the distribution box.
Construction
Phase Conductor
Aluminum 1350-H19 hard tempering, concentric stranded.
Neutral Conductor
Aluminum support conductor with Steel Core (ACSR), concentric stranded.
Insulation
Composed of cross-linked polyethylene XLPE, resistant to UV rays.
Applicable standards
- NTC 5346, ICEA S-76-474.
- NTC 4334, ASTM B-400.
- NTC 309, ASTM B-232.
Certificate
CIDET N° 02619/01336
Operating Temperature
90°C
Operating Voltage
600 V
Identification
• Phase conductors identification by polarity ridges.
Packaging units
Wooden reels in 500 o 1000 m.
Opcional
- Bare Neutral conductor.
- Flame retardant insulation.
- Neutral conductor type AAAC or AAC.
- Identification in color traces.
Ampacity Conditions (Self Supported Multiplex Cables)
- Ampacity to 90°C conductor temperature, 40°C ambient temperature.
- No more than three individual insulated and self-supported conductors per messenger according to NTC 2050, Table 310.15(B)(20).
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania