Aluminum Cables 1350-H19 (AAC)

Products

4 AWG

Nexans ref. 200036

  • Conductor flexibility: Class A
  • Type of cable: Rose
  • Outer Diameter: 5.88 mm
  • Diameter of aluminium wires: 1.96 mm
  • Conductor cross-section: - kcmil
  • Aluminium cross-section: 21.2 mm²
  • Approximate weight: 58.4 kg/km
  • Conductor cross-section (AWG/KCMIL): 4 AWG
  • Max. DC resistance of the conductor at 20°C: 1.387 Ohm/km
  • Ampacity: 138.0 A
  • Short Circuit Current 1 s Max : 2.4 kA
  • Minimum breaking load: 400 kgf

 

2 AWG

Nexans ref. 200037

  • Conductor flexibility: Class AA
  • Type of cable: Iris
  • Outer Diameter: 7.42 mm
  • Diameter of aluminium wires: 2.47 mm
  • Conductor cross-section: - kcmil
  • Aluminium cross-section: 33.6 mm²
  • Approximate weight: 92.8 kg/km
  • Conductor cross-section (AWG/KCMIL): 2 AWG
  • Max. DC resistance of the conductor at 20°C: 0.871 Ohm/km
  • Ampacity: 185.0 A
  • Short Circuit Current 1 s Max : 3.9 kA
  • Minimum breaking load: 613 kgf

 

1/0 AWG

Nexans ref. 200040

  • Conductor flexibility: Class AA
  • Type of cable: Poppy
  • Outer Diameter: 9.36 mm
  • Diameter of aluminium wires: 3.12 mm
  • Conductor cross-section: - kcmil
  • Aluminium cross-section: 53.5 mm²
  • Approximate weight: 147.5 kg/km
  • Conductor cross-section (AWG/KCMIL): 1/0 AWG
  • Max. DC resistance of the conductor at 20°C: 0.548 Ohm/km
  • Ampacity: 247.0 A
  • Short Circuit Current 1 s Max : 6.2 kA
  • Minimum breaking load: 903 kgf

 

2/0 AWG

Nexans ref. 200042

  • Conductor flexibility: Class AA
  • Type of cable: Aster
  • Outer Diameter: 10.51 mm
  • Diameter of aluminium wires: 3.5 mm
  • Conductor cross-section: - kcmil
  • Aluminium cross-section: 67.4 mm²
  • Approximate weight: 186.14 kg/km
  • Conductor cross-section (AWG/KCMIL): 2/0 AWG
  • Max. DC resistance of the conductor at 20°C: 0.435 Ohm/km
  • Ampacity: 286.0 A
  • Short Circuit Current 1 s Max : 7.8 kA
  • Minimum breaking load: 1138 kgf

 

3/0 AWG

Nexans ref. 200044

  • Conductor flexibility: Class AA
  • Type of cable: Phlox
  • Outer Diameter: 11.8 mm
  • Diameter of aluminium wires: 3.93 mm
  • Conductor cross-section: - kcmil
  • Aluminium cross-section: 85 mm²
  • Approximate weight: 234.64 kg/km
  • Conductor cross-section (AWG/KCMIL): 3/0 AWG
  • Max. DC resistance of the conductor at 20°C: 0.345 Ohm/km
  • Ampacity: 330.0 A
  • Short Circuit Current 1 s Max : 9.8 kA
  • Minimum breaking load: 1377 kgf

 

4/0 AWG

Nexans ref. 200045

  • Conductor flexibility: Class AA
  • Type of cable: Oxlip
  • Outer Diameter: 13.25 mm
  • Diameter of aluminium wires: 4.42 mm
  • Conductor cross-section: - kcmil
  • Aluminium cross-section: 107 mm²
  • Approximate weight: 295.95 kg/km
  • Conductor cross-section (AWG/KCMIL): 4/0 AWG
  • Max. DC resistance of the conductor at 20°C: 0.273 Ohm/km
  • Ampacity: 382.0 A
  • Short Circuit Current 1 s Max : 12.4 kA
  • Minimum breaking load: 1737 kgf

 

266.8 KCMIL

Nexans ref. 200047

  • Conductor flexibility: Class AA
  • Type of cable: Daisy
  • Outer Diameter: 14.88 mm
  • Diameter of aluminium wires: 4.96 mm
  • Conductor cross-section: 134.6 kcmil
  • Aluminium cross-section: 134.6 mm²
  • Approximate weight: 373 kg/km
  • Conductor cross-section (AWG/KCMIL): 266.8 KCMIL
  • Max. DC resistance of the conductor at 20°C: 0.217 Ohm/km
  • Ampacity: 443.0 A
  • Short Circuit Current 1 s Max : 15.6 kA
  • Minimum breaking load: 2190 kgf

 

Description

Description

Standards

  • National
    NTC 308; NTC 360

Application

AAC CENTELSA by Nexans cables are used in overhead power transmission and distribution networks.

Construction

Concentric conductor composed of aluminum wires 1350-H19. 

Applicable Standards

  • ASTM B230, NTC 360
  • ASTM B231, NTC 308 

Certificate

RETIE  N°07983 

RETIE N° 00409

Ampacity Conditions

  • Current capacity at ambient temperature 25°C, conductor temperature 75°C, solar emission 1kW/m², absorption and emissivity coefficients 0.5, wind speed 610 mm/sec, at sea level and at 60 Hz.
  • Short circuit current for one (1.0) second, at initial temperature of 75°C and final temperature of 340°C.
  • For all constructions or wiring ME: Modulus of elasticity 6300 kgf/mm², CDL: linear expansion coefficient 23.0 x 10 exp(-6) /°C.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum Alloy 1350-H19

Dimensional characteristics

Dimensional characteristics

Number of aluminium wires
7

Mechanical characteristics

Mechanical characteristics

Hardness type
1350-H19

Usage characteristics

Usage characteristics

Maximum operating temperature
75 °C

Resources

Resources

Documentation

xls — 0 B
xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close