10AWG

Description

Description

Application

Cables for low voltage electrical energy distribution, installations in buildings, inside premises, control panels and electronic circuits. Suitable for places with a high concentration of people, where conductors with a low halogen content and low smoke emission are required, which in the event of a fire will not generate toxic or corrosive gases that may affect the health of people and the condition of equipment and circuits electronics. The cables can be used for installations mentioned in NTC 2050 Article 310.

Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.

Construction

Conductor

Soft copper conductor.

Insulation

Low halogen (LH – Low Halogen), flame retardant (FR – Flame Retardant), low smoke emission (LS – Low Smoke) opaque, dense, toxic and corrosive thermoplastic compound.

Applicable Standards

NTC 6182

Certificate

RETIE N° 07511

RETIE N° 05915

Operating Temperature

75°C

Operating Voltage

600V

Marking

CENTELSA by NEXANS < Calibre AWG / Kcmil >  Cu SINTOX LHFR-LS 600 V 75°C CT - HECHO EN COLOMBIA [M].

Ampacity Conditions

  • Ampacity to 90 °C conductor temperature, 30°C ambient temperature. No more than three current carrying condutores in a duct or pipe. According to NTC 2050, Table 310.15(B)(16).

 

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class B
Conductor material
Soft copper
Conductor shape
Compressed
Insulation
Halogen free polyolefin

Dimensional characteristics

Dimensional characteristics

Approximate weight
62 kg/km
Conductor cross-section
5.26 mm²
Conductor diameter
2.85 mm
Nominal insulation thickness
0.76 mm
Nominal outer diameter
4.45 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Ampacity
35.0 A
Max. DC resistance of the conductor at 20°C
3.417 Ohm/km
Operating voltage
600 V

Usage characteristics

Usage characteristics

Fire retardant
IEC 60332-3-24 (cat C)
Reference
-
RoHS conform
-
Slightly halogenous
IEC 60754-1

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close