- Markets
- Catalogue
- Services and solutions
- Company
- Newsroom
- Tools & Resources
- Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
Premium Nexans Solar Cable PV WIRE
Premium Nexans Solar Cable PV WIRE
Nexans Solar Offer includes premium cables specifically created with high engineered standars. Nexans PV Wire Cable transforms the electrification process.
Read more1/0 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 585 kg/km
- Conductor cross-section: 53.5 mm²
- Nominal insulation thickness: 2.67 mm
- Nominal outer diameter: 14.02 mm
- Ampacity: 170.0 A
- Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km
10AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 83 kg/km
- Conductor cross-section: 5.26 mm²
- Nominal insulation thickness: 1.9 mm
- Nominal outer diameter: 6.81 mm
- Ampacity: 40.0 A
- Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km
12 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 61 kg/km
- Conductor cross-section: 3.31 mm²
- Nominal insulation thickness: 1.9 mm
- Nominal outer diameter: 6.22 mm
- Ampacity: 30.0 A
- Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km
2/0 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 723 kg/km
- Conductor cross-section: 67.4 mm²
- Nominal insulation thickness: 2.67 mm
- Nominal outer diameter: 15.07 mm
- Ampacity: 195.0 A
- Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km
250 Kcmil
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 1309 kg/km
- Conductor cross-section: 127 mm²
- Nominal insulation thickness: 3.05 mm
- Nominal outer diameter: 19.47 mm
- Ampacity: 290.0 A
- Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km
2AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 372 kg/km
- Conductor cross-section: 33.6 mm²
- Nominal insulation thickness: 2.16 mm
- Nominal outer diameter: 11.25 mm
- Ampacity: 130.0 A
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
300 Kcmil
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 1555 kg/km
- Conductor cross-section: 152 mm²
- Nominal insulation thickness: 3.05 mm
- Nominal outer diameter: 20.74 mm
- Ampacity: 320.0 A
- Max. DC resistance of the conductor at 20°C: 0.118 Ohm/km
350 Kcmil
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 1795 kg/km
- Conductor cross-section: 177 mm²
- Nominal insulation thickness: 3.05 mm
- Nominal outer diameter: 21.9 mm
- Ampacity: 350.0 A
- Max. DC resistance of the conductor at 20°C: 0.101 Ohm/km
4 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 249 kg/km
- Conductor cross-section: 21.2 mm²
- Nominal insulation thickness: 2.16 mm
- Nominal outer diameter: 9.84 mm
- Ampacity: 95.0 A
- Max. DC resistance of the conductor at 20°C: 0.847 Ohm/km
4/0 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 1105 kg/km
- Conductor cross-section: 107 mm²
- Nominal insulation thickness: 2.67 mm
- Nominal outer diameter: 17.57 mm
- Ampacity: 260.0 A
- Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km
500 Kcmil
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 2504 kg/km
- Conductor cross-section: 253 mm²
- Nominal insulation thickness: 3.05 mm
- Nominal outer diameter: 24.96 mm
- Ampacity: 430.0 A
- Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km
6 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 171 kg/km
- Conductor cross-section: 13.3 mm²
- Nominal insulation thickness: 2.16 mm
- Nominal outer diameter: 8.72 mm
- Ampacity: 75.0 A
- Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km
600 Kcmil
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 3024 kg/km
- Conductor cross-section: 304 mm²
- Nominal insulation thickness: 3.43 mm
- Nominal outer diameter: 27.67 mm
- Ampacity: 475.0 A
- Max. DC resistance of the conductor at 20°C: 0.059 Ohm/km
750 Kcmil
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 3752 kg/km
- Conductor cross-section: 380 mm²
- Nominal insulation thickness: 3.43 mm
- Nominal outer diameter: 30.1 mm
- Ampacity: 535.0 A
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
8 AWG
Nexans ref.
- Packaging: Drum (1000m)
- Approximate weight: 119 kg/km
- Conductor cross-section: 8.37 mm²
- Nominal insulation thickness: 2.16 mm
- Nominal outer diameter: 7.83 mm
- Ampacity: 55.0 A
- Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km
Description
Description
Standards
-
ProductUL 4703
Solar Premium Cable
Premium Nexans Solar PV WIRE Cable meets all the requirements of the UL 4703 standard. It has a soft copper conductor, with cross-linked polyethylene (XLPE) insulation, free of hazardous substances (RoHS).
Applications and Features
Power supply of low voltage circuits up to 2kV, mainly the connection of photovoltaic solar panels on roofs and solar farms where weather resistance characteristics are required.
Ideal for connection between the strings of photovoltaic solar panels as well as the connection to the combiner box (if applicable) and as the main feeder for the connection of inverter equipment responsible for transforming direct current (DC) from solar energy into alternating current (AC).
Cables suitable for installation in conduit, directly buried, in dry, humid or wet locations, and resistant to UV rays.
In general the cables can be used for systems described in NEC Article 690 part IV (equivalent NTC 2050).
Our PV WIRE cables meet the following characteristics:
- FV-1/Vertical flame test, according to UL 2556 Standard.
- Direct buried installation, complying with impact test according to UL 4703 standard.
- Resistance to solar rays, complying with the test defined in the UL 2556 standard, exposure to 720 hours.
- Cable designed for intermittent partial or total immersion in water according to condition AD7, at a depth between 150 mm and maximum 1 m (low pressure), complying with the test defined in section 14.2.7 of the IEC 60529 standard (Procedure developed by Centelsa by Nexans).
Construction
Conductor
Class B soft temper copper.
Insulation
Thermostable compound Flame retardant (FR) and UV resistant (SR).
Applicable standards
UL 4703
Certificate
RETIE N°06875, RETIE N°07015
Operating temperature
90°C
Operating voltage
2kV
Identification
Insulation in Red and Black color.
Sequential length meter by meter with return to zero.
Packaging Units
1000 m reels. Other packaging units available upon request.
Optional Features available upon request:
Tinned copper conductor or flexible copper conductor, insulation in cross-linked compound free of halogens and low smoke emission. Application of protection additives against rodents and termites. FV-2/VW-1 test.
For more information contact our sales representative.
Ampacity Conditions
- Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit or raceway. NTC 2050, Table 310.15(B)(16).
- The data indicated in this table are subject to normal manufacturing tolerances.
NOTE:
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Nexans Solar Offer
Solar Offer - Key Insights
Solar Project - Phases
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania