Bare Copper Coated Steel Cables and Wires (CCS)
Bare Copper Coated Steel Cables and Wires (CCS)
Bare concentric-lay-stranded conductors made from bare round copper-clad steel wires.
Read more19x5 AWG
Nexans ref.
- Conductor cross-section: 318.789 mm²
- Number of steel wire: 19
- Bare wire diameter: 4.622 mm
- Outer Diameter: 23.11 mm
- Approximate weight: 3677.55 kg/km
- Max. DC resistance of the conductor at 20°C: 0.143 Ohm/km
- Minimum breaking load: 22108 kgf
3x12 AWG
Nexans ref.
- Conductor cross-section: 9.921 mm²
- Number of steel wire: 3
- Bare wire diameter: 2.052 mm
- Outer Diameter: 4.22 mm
- Approximate weight: 65.4 kg/km
- Max. DC resistance of the conductor at 20°C: 4.555 Ohm/km
- Minimum breaking load: 747 kgf
7x12 AWG
Nexans ref.
- Conductor cross-section: 23.167 mm²
- Number of steel wire: 7
- Bare wire diameter: 2.052 mm
- Outer Diameter: 6.16 mm
- Approximate weight: 194.71 kg/km
- Max. DC resistance of the conductor at 20°C: 1.956 Ohm/km
- Minimum breaking load: 1686 kgf
7x7 AWG
Nexans ref.
- Conductor cross-section: 73.847 mm²
- Number of steel wire: 7
- Bare wire diameter: 3.665 mm
- Outer Diameter: 11 mm
- Approximate weight: 608.5 kg/km
- Max. DC resistance of the conductor at 20°C: 0.613 Ohm/km
- Minimum breaking load: 5575 kgf
Description
Description
Application
CCS CENTELSA by Nexans cables and wires are used in power distribution networks for the construction of grounding systems or general use for electrical purposes.
Note: Any other application or use not described above is considered prohibited.
Construction
Cables composed of copper-clad steel wires with high and extra-high strength and conductivities of 30% and 40%.
Applicable Standards
- ASTM B228
- ET-TD-ME01-29
Certificate
RETIE N°08298
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper-clad steel
Conductor shape
Circular
Type of conductor
Stranded
Mechanical characteristics
Mechanical characteristics
Hardness type
High-Strength
Usage characteristics
Usage characteristics
Maximum operating temperature
75 °C
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania