Aluminum Conductors Aluminum-Alloy Reinforced (ACAR)
Aluminum Conductors Aluminum-Alloy Reinforced (ACAR)
Conductor formed by 1350 H19 Aluminum wires and 6201 T81 Aluminum Alloy wires.
Read more250 kcmil (12/7)
Nexans ref. 209938
- Aluminium cross-section: 127 mm²
- Conductor cross-section: 250 kcmil
- Number of aluminium wires: 12
- Diameter of aluminium wires: 2.91 mm
- Number of aluminium alloy 6201 wires: 7
- Diameter of aluminium alloy 6201 wires: 2.91 mm
- Outer Diameter: 14.57 mm
- Approximate weight: 349 kg/km
- Max. DC resistance of the conductor at 20°C: 0.245 Ohm/km
- Ampacity: 417.0 A
- Short Circuit Current 1 s Max : 14.7 kA
- Minimum breaking load: 2813 kgf
300 kcmil (12/7)
Nexans ref. 204036
- Aluminium cross-section: 152 mm²
- Conductor cross-section: 300 kcmil
- Number of aluminium wires: 12
- Diameter of aluminium wires: 3.19 mm
- Number of aluminium alloy 6201 wires: 7
- Diameter of aluminium alloy 6201 wires: 3.19 mm
- Outer Diameter: 15.96 mm
- Approximate weight: 419 kg/km
- Max. DC resistance of the conductor at 20°C: 0.203 Ohm/km
- Ampacity: 468.0 A
- Short Circuit Current 1 s Max : 17.6 kA
- Minimum breaking load: 3348 kgf
350 kcmil (12/7)
Nexans ref. 211568
- Aluminium cross-section: 177 mm²
- Conductor cross-section: 350 kcmil
- Number of aluminium wires: 12
- Diameter of aluminium wires: 3.45 mm
- Number of aluminium alloy 6201 wires: 7
- Diameter of aluminium alloy 6201 wires: 3.45 mm
- Outer Diameter: 17.24 mm
- Approximate weight: 488 kg/km
- Max. DC resistance of the conductor at 20°C: 0.174 Ohm/km
- Ampacity: 515.0 A
- Short Circuit Current 1 s Max : 20.5 kA
- Minimum breaking load: 3814.71 kgf
400 kcmil (12/7)
Nexans ref. 212402
- Aluminium cross-section: 203 mm²
- Conductor cross-section: 400 kcmil
- Number of aluminium wires: 12
- Diameter of aluminium wires: 3.69 mm
- Number of aluminium alloy 6201 wires: 7
- Diameter of aluminium alloy 6201 wires: 3.69 mm
- Outer Diameter: 18.43 mm
- Approximate weight: 558 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Ampacity: 560.0 A
- Short Circuit Current 1 s Max : 23.5 kA
- Minimum breaking load: 4318.19 kgf
500 kcmil (12/7)
Nexans ref. 212737
- Aluminium cross-section: 253 mm²
- Conductor cross-section: 500 kcmil
- Number of aluminium wires: 12
- Diameter of aluminium wires: 4.12 mm
- Number of aluminium alloy 6201 wires: 7
- Diameter of aluminium alloy 6201 wires: 4.12 mm
- Outer Diameter: 20.6 mm
- Approximate weight: 698 kg/km
- Max. DC resistance of the conductor at 20°C: 0.122 Ohm/km
- Ampacity: 645.0 A
- Short Circuit Current 1 s Max : 29.3 kA
- Minimum breaking load: 5352 kgf
650 kcmil (18/19)
Nexans ref. 204360
- Aluminium cross-section: 329 mm²
- Conductor cross-section: 650 kcmil
- Number of aluminium wires: 18
- Diameter of aluminium wires: 3.37 mm
- Number of aluminium alloy 6201 wires: 19
- Diameter of aluminium alloy 6201 wires: 3.37 mm
- Outer Diameter: 23.57 mm
- Approximate weight: 906 kg/km
- Max. DC resistance of the conductor at 20°C: 0.096 Ohm/km
- Ampacity: 755.0 A
- Short Circuit Current 1 s Max : 38.1 kA
- Minimum breaking load: 7530 kgf
750 kcmil (18/19)
Nexans ref. 203807
- Aluminium cross-section: 380 mm²
- Conductor cross-section: 750 kcmil
- Number of aluminium wires: 18
- Diameter of aluminium wires: 3.62 mm
- Number of aluminium alloy 6201 wires: 19
- Diameter of aluminium alloy 6201 wires: 3.62 mm
- Outer Diameter: 25.31 mm
- Approximate weight: 1046 kg/km
- Max. DC resistance of the conductor at 20°C: 0.083 Ohm/km
- Ampacity: 826.0 A
- Short Circuit Current 1 s Max : 44 kA
- Minimum breaking load: 8618 kgf
850 kcmil (18/19)
Nexans ref. 211676
- Aluminium cross-section: 431 mm²
- Conductor cross-section: 850 kcmil
- Number of aluminium wires: 18
- Diameter of aluminium wires: 3.85 mm
- Number of aluminium alloy 6201 wires: 19
- Diameter of aluminium alloy 6201 wires: 3.85 mm
- Outer Diameter: 26.95 mm
- Approximate weight: 1185 kg/km
- Max. DC resistance of the conductor at 20°C: 0.073 Ohm/km
- Ampacity: 894.0 A
- Short Circuit Current 1 s Max : 49.8 kA
- Minimum breaking load: 9707 kgf
950 kcmil (18/19)
Nexans ref. 200032
- Aluminium cross-section: 481 mm²
- Conductor cross-section: 950 kcmil
- Number of aluminium wires: 18
- Diameter of aluminium wires: 4.07 mm
- Number of aluminium alloy 6201 wires: 19
- Diameter of aluminium alloy 6201 wires: 4.07 mm
- Outer Diameter: 28.49 mm
- Approximate weight: 1324 kg/km
- Max. DC resistance of the conductor at 20°C: 0.066 Ohm/km
- Ampacity: 959.0 A
- Short Circuit Current 1 s Max : 55.7 kA
- Minimum breaking load: 10841 kgf
1200 kcmil (18/19)
Nexans ref. 200031
- Aluminium cross-section: 608 mm²
- Conductor cross-section: 1200 kcmil
- Number of aluminium wires: 18
- Diameter of aluminium wires: 4.57 mm
- Number of aluminium alloy 6201 wires: 19
- Diameter of aluminium alloy 6201 wires: 4.57 mm
- Outer Diameter: 32.02 mm
- Approximate weight: 1673 kg/km
- Max. DC resistance of the conductor at 20°C: 0.052 Ohm/km
- Ampacity: 1112.0 A
- Short Circuit Current 1 s Max : 70.4 kA
- Minimum breaking load: 13744 kgf
Description
Description
Standards
-
ProductASTM B 230; ASTM B 398
Application
ACAR CENTELSA by Nexans cables are used in overhead power transmission and distribution networks. Their good breaking load-to-weight ratio makes ACAR cables suitable for long-span transmission systems.
Note: Any other application or use not described above is considered prohibited.
Construction
1350 H19 aluminum wires stranded over a concentric conductor of 6201 T81 aluminum alloy wires.
Most ACAR cable constructions have a 6201 aluminum alloy core; in some configurations, the 6201 aluminum alloy wires are arranged in layers, combined with 1350 H19 aluminum wires.
Applicable Standards
- ASTM B398, NTC 2729
- ASTM B230, NTC 360
- ASTM B524, NTC 6065
Certificate
RETIE N°01207
Ampacity Conditions
- Current capacity at ambient temperature 25°C, conductor temperature 75°C, solar emission 1kW/m², absorption and emissivity coefficients 0.5, wind speed 610 mm/sec, at sea level and at 60 Hz.
- Short circuit current for one (1.0) second, at initial temperature of 75°C and final temperature of 340°C.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania