3x6+8AWG

Description

Description

Standards

  • Product
    ASTM B 3; ASTM B 8; ICEA S-95-658; NTC 1099-1
  • National
    NTC 307; NTC 359

Application

Low voltage distribution systems, from secondary distribution grid to user equipment measurement.

Construction

Conductor

Soft copper conductors, concentric stranded, class B.

Insulation

Polyethylene (PE) compound resistant to mechanical stress during cable installation and operation.

Assembly

Insulated phase and neutral conductors assembled on which a polyester tape reinforced with fiberglass is placed in a helical shape.

Overall Jacket

External cover with thermoplastic compound in polyvinyl chloride (PVC), flame retardant (FR), resistant to abrasion, heat, moisture, and sunlight resistant (SR).

Applicable Standards

  • ET-112 "Technical Specification"
  • NTC 1099-1, ICEA S-95-658
  • NTC 307, ASTM B8
  • NTC 359, ASTM B3

Certificate

RETIE N° 06409

Operating Temperature

75 °C

Operating Voltage

600 V

Identification

  • Phase conductors color: Yellow-Blue-Red.
  • Neutral conductor color: White.

Ampacity Conditions

  • Ampacity for ambient temperature 30°C, conductor temperature 75°C, no more than three current carrying conductors in a duct according to NTC 2050 Table 310.15(B)(16)
  • Data indicated in this table are subject to normal manufacturing tolerances.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulation
PE
Outer sheath
PVC
Conductor flexibility
Class B
Conductor shape
Compact stranded

Dimensional characteristics

Dimensional characteristics

Conductor diameter
4.28 mm
Conductor cross-section
13.3 mm²
Neutral conductor section (when smaller)
8.37 mm²
Neutral Conductor Diameter
3.39 mm
Insulation thickness of neutral conductor
0.76 mm
Approximate weight
634.62 kg/km
Nominal insulation thickness
1.14 mm
Nominal outer diameter
18.67 mm
Number of cores
4

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
1.349 Ohm/km
Ampacity
65.0 A
Max.DC-resist of conc neutral/earth at 20°C
2.144 Ohm/km
Rated Voltage Uo/U (Um)
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good

Usage characteristics

Usage characteristics

Weather resistance
Yes
Maximum operating temperature
75 °C
RoHS compliant
Yes
U.V resistance
Yes (720 hours)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close