- Markets
- Catalogue
- Services and solutions
- Company
- Newsroom
- Tools & Resources
- Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
COVERED CABLES (Semi-insulated)
COVERED CABLES (Semi-insulated)
ACSR conductor with XLPE semiconductor layer, XLPE inner layer and XLPE-TK external layer with tracking and weather resistant.
Read more2AWG
Nexans ref. 200234
- Conductor diameter: 7.59 mm
- Outer Diameter: 17.54 mm
- Approximate weight: 301 kg/km
- Average sheath thickness: 3.82 mm
- Conductor cross-section: 39.25 mm²
- Nominal outer diameter: 16.51 mm
- Nominal outer sheath thickness: 3.82 mm
- Max. DC resistance of the conductor at 20°C: 0.846 Ohm/km
- Operating voltage: 15 kV
1/0AWG
Nexans ref. 200238
- Conductor diameter: 9.27 mm
- Outer Diameter: 18.97 mm
- Approximate weight: 427.52 kg/km
- Average sheath thickness: 3.82 mm
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 18.43 mm
- Nominal outer sheath thickness: 3.82 mm
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
- Operating voltage: 15 kV
2/0AWG
Nexans ref. 200240
- Conductor diameter: 10.4 mm
- Outer Diameter: 19.56 mm
- Approximate weight: 485 kg/km
- Average sheath thickness: 3.82 mm
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 19.56 mm
- Nominal outer sheath thickness: 3.82 mm
- Max. DC resistance of the conductor at 20°C: 0.422 Ohm/km
- Operating voltage: 15 kV
4/0AWG
Nexans ref. 211703
- Conductor diameter: 13.54 mm
- Outer Diameter: 23.64 mm
- Approximate weight: 691 kg/km
- Average sheath thickness: 3.82 mm
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 22.47 mm
- Nominal outer sheath thickness: 3.82 mm
- Max. DC resistance of the conductor at 20°C: 0.265 Ohm/km
- Operating voltage: 15 kV
266.8kcmil
Nexans ref. 211704
- Conductor diameter: 14.18 mm
- Outer Diameter: 24.16 mm
- Approximate weight: 761 kg/km
- Average sheath thickness: 3.82 mm
- Conductor cross-section: 135 mm²
- Nominal outer diameter: 24.16 mm
- Nominal outer sheath thickness: 3.82 mm
- Max. DC resistance of the conductor at 20°C: 0.216 Ohm/km
- Operating voltage: 15 kV
1/0AWG
Nexans ref. 208284
- Conductor diameter: 9.27 mm
- Outer Diameter: 26.57 mm
- Approximate weight: 681.1 kg/km
- Average sheath thickness: 7.63 mm
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 26.57 mm
- Nominal outer sheath thickness: 7.63 mm
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
- Operating voltage: 35 kV
2/0AWG
Nexans ref. 209182
- Conductor diameter: 10.4 mm
- Outer Diameter: 27.77 mm
- Approximate weight: 745 kg/km
- Average sheath thickness: 7.63 mm
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 27.77 mm
- Nominal outer sheath thickness: 7.63 mm
- Max. DC resistance of the conductor at 20°C: 0.422 Ohm/km
- Operating voltage: 35 kV
4/0AWG
Nexans ref. 200289
- Conductor diameter: 13.54 mm
- Outer Diameter: 30.05 mm
- Approximate weight: 982 kg/km
- Average sheath thickness: 7.63 mm
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 30.05 mm
- Nominal outer sheath thickness: 7.63 mm
- Max. DC resistance of the conductor at 20°C: 0.265 Ohm/km
- Operating voltage: 35 kV
266.8kcmil
Nexans ref. 211853
- Conductor diameter: 14.18 mm
- Outer Diameter: 31.76 mm
- Approximate weight: 994 kg/km
- Average sheath thickness: 7.63 mm
- Conductor cross-section: 135 mm²
- Nominal outer diameter: 31.76 mm
- Nominal outer sheath thickness: 7.63 mm
- Max. DC resistance of the conductor at 20°C: 0.216 Ohm/km
- Operating voltage: 35 kV
266.8kcmil
Nexans ref.
- Conductor diameter: 14.18 mm
- Outer Diameter: 37.5 mm
- Approximate weight: 1332 kg/km
- Average sheath thickness: 10.15 mm
- Conductor cross-section: 135 mm²
- Nominal outer diameter: 37.5 mm
- Nominal outer sheath thickness: 10.15 mm
- Max. DC resistance of the conductor at 20°C: 0.216 Ohm/km
- Operating voltage: 46 kV
Description
Description
Standards
-
ProductASTM B 232
-
NationalNTC 5909
Applications
COVERED (Semi-insulated) cables are used as power distribution lines in wooded areas. They offer greater reliability of operation and compatibility with the environment.
Construction
Conductor
Aluminum Conductor with Steel Core (ACSR), concentric stranded with moisture migration blocking.
Layer 1
Conductor shielding in semiconductor cross-linked polyethylene (XLPE).
Layer 2
Cross-linked polyethylene compound (XLPE).
Layer 3
Cross-linked polyethylene compound (XLPE-TK) with abrasion, tracking and weather resistant.
Applicable Standars
- NTC 5909
- ASTM B232
Certificate
RETIE N°04885/02711
Operating Temperature
90 °C
Operating Voltage
15 kV, 35 kV
Optional: Aluminum 1350-H19 (AAC) and Aluminum alloy 6201-T81 (AAAC), concentric stranded. Outer layer in high-density polyethylene (HDPE). Operating voltage to 46 kV.
Ampacity Conditions
- Current capacity at ambient temperature 25°C, conductor temperature 75°C, total emission 1 Kw/m², absorption and emissivity coefficients 0.5, wind speed 610 mm/sec, at sea level and at 60 Hz.
-The Data shown in the table are subject to normal manufacturing tolerances .
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania