COVERED OVERHEAD CABLES (Tree Wire) 3C - ACSR Conductor
COVERED OVERHEAD CABLES (Tree Wire) 3C - ACSR Conductor
ACSR conductor with XLPE semiconductor layer, XLPE inner layer and XLPE-TK external layer with tracking and weather resistant.
Read more2AWG
Nexans ref. 200234
- Conductor cross-section: 33.6 mm²
- Conductor diameter: 7.59 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 17.54 mm
- Approximate weight: 301 kg/km
- Max. DC resistance of the conductor at 20°C: 0.846 Ohm/km
- Operating voltage: 15 kV
1/0AWG
Nexans ref. 200238
- Conductor cross-section: 53.5 mm²
- Conductor diameter: 9.27 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 18.97 mm
- Approximate weight: 427.52 kg/km
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
- Operating voltage: 15 kV
2/0AWG
Nexans ref. 200240
- Conductor cross-section: 67.4 mm²
- Conductor diameter: 10.4 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 19.56 mm
- Approximate weight: 485 kg/km
- Max. DC resistance of the conductor at 20°C: 0.422 Ohm/km
- Operating voltage: 15 kV
4/0AWG
Nexans ref. 211703
- Conductor cross-section: 107 mm²
- Conductor diameter: 13.54 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 23.64 mm
- Approximate weight: 691 kg/km
- Max. DC resistance of the conductor at 20°C: 0.265 Ohm/km
- Operating voltage: 15 kV
266.8kcmil
Nexans ref. 211704
- Conductor cross-section: 135 mm²
- Conductor diameter: 14.18 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 24.16 mm
- Approximate weight: 761 kg/km
- Max. DC resistance of the conductor at 20°C: 0.216 Ohm/km
- Operating voltage: 15 kV
1/0AWG
Nexans ref. 208284
- Conductor cross-section: 53.5 mm²
- Conductor diameter: 9.27 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 26.57 mm
- Approximate weight: 681.1 kg/km
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
- Operating voltage: 35 kV
2/0AWG
Nexans ref. 209182
- Conductor cross-section: 67.4 mm²
- Conductor diameter: 10.4 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 27.77 mm
- Approximate weight: 745 kg/km
- Max. DC resistance of the conductor at 20°C: 0.422 Ohm/km
- Operating voltage: 35 kV
4/0AWG
Nexans ref. 200289
- Conductor cross-section: 107 mm²
- Conductor diameter: 13.54 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 30.05 mm
- Approximate weight: 982 kg/km
- Max. DC resistance of the conductor at 20°C: 0.265 Ohm/km
- Operating voltage: 35 kV
266.8kcmil
Nexans ref. 211853
- Conductor cross-section: 135 mm²
- Conductor diameter: 14.18 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 31.76 mm
- Approximate weight: 994 kg/km
- Max. DC resistance of the conductor at 20°C: 0.216 Ohm/km
- Operating voltage: 35 kV
266.8kcmil
Nexans ref.
- Conductor cross-section: 135 mm²
- Conductor diameter: 14.18 mm
- Average insulation thickness: 5.7 mm
- Average sheath thickness: 4.45 mm
- Outer Diameter: 37.5 mm
- Approximate weight: 1332 kg/km
- Max. DC resistance of the conductor at 20°C: 0.216 Ohm/km
- Operating voltage: 46 kV
Description
Description
Standards
-
ProductASTM B 232
-
NationalNTC 5909
Applications
COVERED OVERHEAD CABLES 3C (3 layers) are used as power distribution lines in wooded areas. They offer greater reliability of operation and compatibility with the environment.
Construction
Conductor
Aluminum Conductor with Steel Core (ACSR), concentric stranded with moisture migration blocking.
Layer 1
Extruded conductor shielding in semiconductive Cross-linked Polyethylene (XLPE).
Layer 2
Extruded Cross-linked Polyethylene insulation compound (XLPE)
Layer 3
Extruded Cross-linked Polyethylene covering compound with abrasion, tracking and weather resistance (XLPE-TK).
Applicable Standars
- NTC 5909
- ASTM B232
Certificate
RETIE N°04885/02711
Operating Temperature
90 °C
Operating Voltage
15 kV, 35 kV
Optional: Aluminum 1350-H19 (AAC) concentric stranded. Outer layer in high-density polyethylene (HDPE). Operating voltage to 46 kV.
Ampacity Conditions - Covered Cables
- Current capacity at ambient temperature 25°C, conductor temperature 90°C, total emission 1 Kw/m², absorption and emissivity coefficients 0.5, wind speed 610 mm/sec, at sea level and at 60 Hz.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania