COVERED OVERHEAD CABLES (Tree Wire) 2C - ACSR Conductor
COVERED OVERHEAD CABLES (Tree Wire) 2C - ACSR Conductor
ACSR conductor with XLPE semiconductor layer and XLPE-TK external layer with tracking and weather resistant.
Read more2AWG
Nexans ref. 210569
- Conductor diameter: 7.59 mm
- Outer Diameter: 14.73 mm
- Approximate weight: 262.2 kg/km
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 14.73 mm
- Max. DC resistance of the conductor at 20°C: 0.846 Ohm/km
1/0AWG
Nexans ref. 210587
- Conductor diameter: 9.27 mm
- Outer Diameter: 16.65 mm
- Approximate weight: 365.85 kg/km
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 16.65 mm
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
2/0AWG
Nexans ref. 207328
- Conductor diameter: 10.4 mm
- Outer Diameter: 17.78 mm
- Approximate weight: 436 kg/km
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 17.78 mm
- Max. DC resistance of the conductor at 20°C: 0.422 Ohm/km
4/0AWG
Nexans ref. 211401
- Conductor diameter: 13.54 mm
- Outer Diameter: 20.49 mm
- Approximate weight: 630.55 kg/km
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 20.49 mm
- Max. DC resistance of the conductor at 20°C: 0.265 Ohm/km
Description
Description
Standards
-
ProductASTM B 232
-
NationalNTC 5909
Applications
COVERED OVERHEAD CABLES 2C (2 layers) are used as power distribution lines in wooded areas. They offer greater reliability of operation and compatibility with the environment.
Construction
Conductor
Aluminum Conductor with Steel Core (ACSR), concentric stranded with moisture migration blocking.
Layer 1
Conductor shielding in semiconductor cross-linked polyethylene (XLPE).
Layer 2
Cross-linked polyethylene compound (XLPE-TK) with abrasion, tracking and weather resistant.
Applicable Standars
- NTC 5909
- ASTM B232
Certificate
RETIE N°04885/02711
Operating Temperature
90 °C
Operating Voltage
15 kV
Optional: Aluminum 1350-H19 (AAC) and Aluminum alloy 6201-T81 (AAAC), concentric stranded. Outer layer in high-density polyethylene (HDPE). Operating voltage to 35 kV, 46 kV.
Ampacity Conditions - Covered Cables
- Current capacity at ambient temperature 25°C, conductor temperature 90°C, total emission 1 Kw/m², absorption and emissivity coefficients 0.5, wind speed 610 mm/sec, at sea level and at 60 Hz.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania