Read more123.3 kcmil
Nexans ref. 200255
- Conductor cross-section: 62.5 mm²
- Conductor diameter: 9.81 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 18.97 mm
- Approximate weight: 379.71 kg/km
- Max. DC resistance of the conductor at 20°C: 0.547 Ohm/km
- Operating voltage: 15 kV
155.4 kcmil
Nexans ref. 209313
- Conductor cross-section: 78.7 mm²
- Conductor diameter: 11.01 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 20.17 mm
- Approximate weight: 443.75 kg/km
- Max. DC resistance of the conductor at 20°C: 0.435 Ohm/km
- Operating voltage: 15 kV
246.9 kcmil
Nexans ref. 212819
- Conductor cross-section: 125 mm²
- Conductor diameter: 13.88 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 23.04 mm
- Approximate weight: 618.74 kg/km
- Max. DC resistance of the conductor at 20°C: 0.273 Ohm/km
- Operating voltage: 15 kV
312.8 kcmil
Nexans ref. 200256
- Conductor cross-section: 158 mm²
- Conductor diameter: 15.81 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 24.97 mm
- Approximate weight: 734.57 kg/km
- Max. DC resistance of the conductor at 20°C: 0.215 Ohm/km
- Operating voltage: 15 kV
394.5 kcmil
Nexans ref. 212652
- Conductor cross-section: 200 mm²
- Conductor diameter: 17.75 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 26.91 mm
- Approximate weight: 880.02 kg/km
- Max. DC resistance of the conductor at 20°C: 0.171 Ohm/km
- Operating voltage: 15 kV
559.5 kcmil
Nexans ref. 212653
- Conductor cross-section: 284 mm²
- Conductor diameter: 21.14 mm
- Average insulation thickness: 1.91 mm
- Average sheath thickness: 1.91 mm
- Outer Diameter: 30.3 mm
- Approximate weight: 1166.56 kg/km
- Max. DC resistance of the conductor at 20°C: 0.12 Ohm/km
- Operating voltage: 15 kV
123.3 kcmil
Nexans ref. 212717
- Conductor cross-section: 62.5 mm²
- Conductor diameter: 9.81 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 26.57 mm
- Approximate weight: 633.29 kg/km
- Max. DC resistance of the conductor at 20°C: 0.547 Ohm/km
- Operating voltage: 35 kV
155.4 kcmil
Nexans ref. 209314
- Conductor cross-section: 78.7 mm²
- Conductor diameter: 11.01 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 27.77 mm
- Approximate weight: 710.65 kg/km
- Max. DC resistance of the conductor at 20°C: 0.435 Ohm/km
- Operating voltage: 35 kV
246.9 kcmil
Nexans ref. 212909
- Conductor cross-section: 125 mm²
- Conductor diameter: 13.88 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 30.64 mm
- Approximate weight: 917.49 kg/km
- Max. DC resistance of the conductor at 20°C: 0.273 Ohm/km
- Operating voltage: 35 kV
312.8 kcmil
Nexans ref. 209315
- Conductor cross-section: 158 mm²
- Conductor diameter: 15.81 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 32.57 mm
- Approximate weight: 1054.74 kg/km
- Max. DC resistance of the conductor at 20°C: 0.215 Ohm/km
- Operating voltage: 35 kV
394.5 kcmil
Nexans ref. 212636
- Conductor cross-section: 200 mm²
- Conductor diameter: 17.75 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 34.51 mm
- Approximate weight: 1221.72 kg/km
- Max. DC resistance of the conductor at 20°C: 0.171 Ohm/km
- Operating voltage: 35 kV
559.5 kcmil
Nexans ref. 213147
- Conductor cross-section: 284 mm²
- Conductor diameter: 21.14 mm
- Average insulation thickness: 4.45 mm
- Average sheath thickness: 3.18 mm
- Outer Diameter: 37.9 mm
- Approximate weight: 1545.89 kg/km
- Max. DC resistance of the conductor at 20°C: 0.12 Ohm/km
- Operating voltage: 35 kV
Description
Description
Standards
-
ProductASTM B 398; ASTM B 399
-
NationalNTC 5909
Applications
COVERED OVERHEAD CABLES (Tree Wire) 3C (3 layers) are used as power transmission and distribution lines in wooded areas. They offer greater reliability of operation and compatibility with the environment.
Note: Any other application or use not described above is considered prohibited.
Construction
Conductor
Aluminum Alloy 6201-T81 Conductor (AAAC), concentric stranded.
Layer 1
Extruded conductor shielding in semiconductive Cross-linked Polyethylene (XLPE).
Layer 2
Extruded Cross-linked Polyethylene insulation compound (XLPE).
Layer 3
Extruded Cross-linked Polyethylene covering compound with abrasion, tracking and weather resistance (XLPE-TK).
Applicable Standars
- ASTM B398
- ASTM B399
- NTC 5909
Certificate
CIDET N°04885
CIDET N°02711
Operating Temperature
90 °C
Operating Voltage
15 kV, 35 kV
Optional: Outer layer in High-Density Polyethylene (HDPE). Operating voltage of 25 kV or 46 kV.
Ampacity Conditions - Covered Cables
- Current capacity at ambient temperature 25°C, conductor temperature 90°C, total emission 1 Kw/m², absorption and emissivity coefficients 0.5, wind speed 610 mm/sec, at sea level and at 60 Hz.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania