NA2XSY 20/35 kV PH+PC; ABNT NBR 6251; ABNT NBR 7286; Anti-rodent
NA2XSY 20/35 kV PH+PC; ABNT NBR 6251; ABNT NBR 7286; Anti-rodent
Power distribution in medium voltage.
Read moreNA2XSY 20/35 kV 240 mm2 PH16
Nexans ref. P00034148-0
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.0 mm
- Diameter over insulation: 37.1 mm
- Diameter over screen: 40.5 mm
- Diameter over Sheath: 45.5 mm
- Approximate weight: 2115 kg/km
NA2XSY 20/35 kV 300 mm2 PH16
Nexans ref. P00034149-0
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.4 mm
- Diameter over insulation: 39.5 mm
- Diameter over screen: 42.8 mm
- Diameter over Sheath: 48 mm
- Approximate weight: 2385 kg/km
NA2XSY 20/35 kV 400 mm2 PH16
Nexans ref. P00034150-0
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.1 mm
- Diameter over insulation: 42.2 mm
- Diameter over screen: 45.5 mm
- Diameter over Sheath: 50.9 mm
- Approximate weight: 2757 kg/km
NA2XSY 20/35 kV 500 mm2 PH16
Nexans ref. P00034151-0
- Conductor cross-section: 500 mm²
- Conductor diameter: 26.2 mm
- Diameter over insulation: 45.3 mm
- Diameter over screen: 48.7 mm
- Diameter over Sheath: 54.3 mm
- Approximate weight: 3220 kg/km
NA2XSY 20/35 kV 630 mm2 PH16
Nexans ref. P00034152-0
- Conductor cross-section: 630 mm²
- Conductor diameter: 29.8 mm
- Diameter over insulation: 48.9 mm
- Diameter over screen: 52.3 mm
- Diameter over Sheath: 58 mm
- Approximate weight: 3775 kg/km
Description
Description
Standards
-
ProductABNT NBR 6251 ; ABNT NBR 7287 ; ICEA S-93-639; IEC 60228; NTP-IEC 60228
-
TestIEC 60332-1-2; IEC 60811-401; IEC 60811-402; IEC 60811-409; IEC 60811-501; IEC 60811-502; IEC 60811-504; IEC 60811-505; IEC 60811-506; IEC 60811-507; IEC 60811-508; IEC 60811-509; UL 2556
Applications
Power distribution in medium voltage. In power plants and electrical substations, industrial and operation installations, in residential areas and mining installations, in dry or wet locations.
Construction
1. Conductor: Compact round aluminium 1350, class 2.
2. Inner semi-conductor: Extruded.
3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).
4. External semi-conductor: Extruded strippable.
These last three components extruded CV (continuous vulcanization) triple extrusion in dry cure process.
5. Screen: Copper wires + copper tape in open helix.
6. Tape: Polyester tape.
7. Outer sheath: Compound polyvinyl chloride PVC with antirodent compound.
Main characteristics
Excellent properties against heat aging. Resistance to abrasion, moisture and sunlight. Adequate resistance to greases and oils. Flame retardant. Resistance to attack by rodents.
Cross section:
From 240 mm2 up to 630 mm2.
Packing:
Non returnable wooden reels.
Colour:
Insulation: Natural.
Outer sheath: Black.
Standards
National standards
NTP-IEC 60228: Conductors of insulated cables.
International standards
IEC 60228: Conductors of insulated cables.
ABNT NBR 6251: Insulated power cables, for rated voltages 1 kV up to 35 kV - Constructive requirements.
ABNT NBR 7287: Power cables extruded cross-linked polyethylene insulated power cable for rated voltages from 1 up to 35 kV - Performace requirements.
IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.
UL 2556: Wire and Cable Test Methods. Section 9.3:FT1 (Vertical-Specimen) Flame Test.
IEC 60811-401: Thermal ageing methods. Ageing in an air oven.
IEC 60811-402: Water absorption tests.
IEC 60811-409: Loss of mass test for thermoplastic insulations and sheaths.
IEC 60811-501: Test for determining the mechanical properties.
IEC 60811-502: Shrinkage test for insulations.
IEC 60811-504: Bending test at low temperature for insulation and sheaths.
IEC 60811-505: Elongation at low temperature for insulations and sheaths.
IEC 60811-506: Impact test at low temperature for insulations and sheaths.
IEC 60811-507: Hot set test for cross-linked materials.
IEC 60811-508: Pressure test at high temperature for insulation and sheaths.
IEC 60811-509: Test for resistance of insulations and sheaths to cracking.
ICEA S-93-639: 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy. Section 9.4.2: Oil Immersion Test.
UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.
BENDING RADIUS INSTALLED IN M.V
R=Dxf
R: Bending radius when installed (mm)
D: Diameter over sheath (mm)
f: Multiplicative factor; given the following table:
Bending radius factor MV
Calculation of Current Condition Single core Medium Voltage
CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 14039
Maximum conductor temperature: 90°C.
Ambient air temperature: 30°C.
Ground temperature: 20°C.
Depth of laying: 0,9 m.
Thermal resistivity of soil: 1,5 K.m/W.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Marking:
INDECO S.A. NA2XSY 20/35 kV - Cross section - PH(Screen section) - Year - Sequential length.