TECK 90 600 V Multi core with bare ground conductor

Products

TECK 90 600 V 2x10+1x12 AWG

Nexans ref. P00026242-0

  • Packaging: Cut to length (m)
  • Conductor shape: Compressed Stranded
  • Conductor diameter: 2.8 mm
  • Diameter over Sheath: 17.5 mm
  • Approximate weight: 386 kg/km

 

TECK 90 600 V 2x8+1x10 AWG

Nexans ref. P00028672-1

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 3.4 mm
  • Diameter over Sheath: 21.1 mm
  • Approximate weight: 565 kg/km

 

TECK 90 600 V 3x8+1x10 AWG

Nexans ref. P00024641-4

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 3.4 mm
  • Diameter over Sheath: 22 mm
  • Approximate weight: 678 kg/km

 

TECK 90 600 V 4x8+1x10 AWG

Nexans ref. P00031836-0

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 3.4 mm
  • Diameter over Sheath: 23.5 mm
  • Approximate weight: 803 kg/km

 

TECK 90 600 V 3x6+1x8 AWG

Nexans ref. P00014029-4

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 4.3 mm
  • Diameter over Sheath: 23.9 mm
  • Approximate weight: 892 kg/km

 

TECK 90 600 V 4x6+1x8 AWG

Nexans ref. P00034392-0

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 4.3 mm
  • Diameter over Sheath: 27 mm
  • Approximate weight: 1253 kg/km

 

TECK 90 600 V 3x4+1x8 AWG

Nexans ref. P00024640-6

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 5.4 mm
  • Diameter over Sheath: 27.7 mm
  • Approximate weight: 1361 kg/km

 

TECK 90 600 V 3x2+1x6 AWG

Nexans ref. P00024639-6

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 6.8 mm
  • Diameter over Sheath: 31.7 mm
  • Approximate weight: 1934 kg/km

 

TECK 90 600 V 3x1/0+1x6 AWG

Nexans ref. P00027141-2

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 8.6 mm
  • Diameter over Sheath: 36.9 mm
  • Approximate weight: 2688 kg/km

 

TECK 90 600 V 3x2/0+1x6 AWG

Nexans ref. P00029829-2

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 9.7 mm
  • Diameter over Sheath: 39.2 mm
  • Approximate weight: 3161 kg/km

 

TECK 90 600 V 4x2/0+1x6 AWG

Nexans ref. P00028624-1

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 9.7 mm
  • Diameter over Sheath: 42.9 mm
  • Approximate weight: 3834 kg/km

 

TECK 90 600 V 3x4/0+1x4 AWG

Nexans ref. P00024642-5

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 12.3 mm
  • Diameter over Sheath: 45.1 mm
  • Approximate weight: 4371 kg/km

 

TECK 90 600 V 3x350 kcmil+1x3 AWG

Nexans ref. P00031835-0

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 15.8 mm
  • Diameter over Sheath: 56.3 mm
  • Approximate weight: 6872 kg/km

 

TECK 90 600 V 3x350 kcmil+1x1/0 AWG

Nexans ref. P00027142-2

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 15.8 mm
  • Diameter over Sheath: 55.6 mm
  • Approximate weight: 7025 kg/km

 

TECK 90 600 V 3x500 kcmil+1x3 AWG

Nexans ref. P00031833-0

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 18.9 mm
  • Diameter over Sheath: 63.5 mm
  • Approximate weight: 9299 kg/km

 

TECK 90 600 V 3x500 kcmil+1x2 AWG

Nexans ref. P00023477-4

  • Packaging: Cut to length (m)
  • Conductor shape: Compact stranded
  • Conductor diameter: 18.9 mm
  • Diameter over Sheath: 63.5 mm
  • Approximate weight: 9362 kg/km

 

Description

Description

Standards

  • Product
    CSA C22.2 N° 131; CSA C22.2 N° 2556; CSA C22.2 N° 38
  • Test
    CSA C22.2 N° 03-01; UL 2556

Application:

General application in low voltage distribution networks in operating stations where high mechanical strength is required. The interlocked aluminum armour gives greater flexibility compared to the traditional steel armour and the type of conformation of the same make has a high resistance to loads that could be placed on it. Class I, Div.2 and Class II, Div.2 hazardous locations per NEC.

Construction:

1. Conductor: Soft copper, class B.

2. Insulation: Cross linked polyethylene XLPE.

3. Bare grounding conductor: Soft copper, class B.

4. Inner covering: Anti-flame compound polyvinyl chloride PVC.

5. Armour: Interlocked aluminum tape.

6. Outer sheath: Anti-flame compound polyvinyl chloride PVC.

Main characteristics:

Resistance to abrasion and oils. Resistance to weather and sunlight. Its armour provides additional mechanical protection and provides greater flexibility compared with other types of armour. Does not propagate the FT-1 flame. Fire retardant according to C22.2 No 0.3-01/FT-4. Resistance to attack by rodents.

Gauge:

From 14 AWG up to 500 kcmil.

Marking:

For gauges equal to or smaller than 8 AWG: INDECO S.A. TECK90(XLPE) (Nb. cores x Gauge phase cond. + Gauge ground. cond.) 0,6 kV -25C FT1 FT4 SR CSA 255079 - Year - Sequential length.

For gauges higher than 8 AWG: INDECO S.A. TECK90(XLPE) (Nb. cores x Gauge phase cond. + Gauge ground. cond.) 0,6 kV -40C FT1 FT4 SR CSA 255079 - year - Sequential length.

Packing:

Non returnable wooden reels.

Colour:

Insulation: See core identification.

Outer sheath: Black.

International standards

CSA C22.2 Nº 131-14: Type TECK 90 cable.

CSA C22.2 Nº 38-14: Thermoset-insulated wires and cables.

CSA C22.2 Nº 03-01: Test methods for electrical wires and cables.

CSA C22.2 Nº 2556-15: Wire and cable test methods.

UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.

UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.

BENDING RADIUS WHEN INSTALLED

R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).

Calculation of Current Condition TECK 90

BASED ON CEC, PART 1, TABLE 2

Maximum conductor temperature: 90°C.

Ambient temperature: 30°C.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulating material
XLPE
Inner sheath
Flame retardant PVC
Armour type
Interlocked aluminum tape
Outer sheath
Flame retardant PVC
Sheath colour
Black
Conductor flexibility
Class B ASTM B8

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Excellent

Usage characteristics

Usage characteristics

Flame retardant
Vertical Test - FT1 (CSA C22.2 No. 2556/9.3)
Fire retardant
FT4 (C22.2 No. 0.3-01/4.11.4)
Oil resistance
Good
Rodent protection
Corrugated aluminium tape
Bending factor when installed
8 (xD)
U.V resistance
CSA C22.2 N° 2556 – Sunlight Resistance
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close