Single Core XHHW-2 TC
Single Core XHHW-2 TC
Soft copper conductor, insulation in XLPE type XHHW-2.
Read more14AWG
Nexans ref. 10028138
- Approximate weight: 28 kg/km
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 3.37 mm
- Max. DC resistance of the conductor at 20°C: 8.629 Ohm/km
- Ampacity: 25.0 A
12AWG
Nexans ref. 10028139
- Approximate weight: 40 kg/km
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 3.82 mm
- Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km
- Ampacity: 30.0 A
10AWG
Nexans ref. 10028140
- Approximate weight: 60 kg/km
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 4.39 mm
- Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km
- Ampacity: 40.0 A
6AWG
Nexans ref. 10028142
- Approximate weight: 146 kg/km
- Nominal insulation thickness: 1.14 mm
- Nominal outer diameter: 6.81 mm
- Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km
- Ampacity: 75.0 A
1/0AWG
Nexans ref. 10028155
- Approximate weight: 537 kg/km
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 11.66 mm
- Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km
- Ampacity: 170.0 A
2/0AWG
Nexans ref. 10025798
- Approximate weight: 665 kg/km
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 12.71 mm
- Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km
- Ampacity: 195.0 A
3/0AWG
Nexans ref. 10028243
- Approximate weight: 842 kg/km
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 14.33 mm
- Max. DC resistance of the conductor at 20°C: 0.211 Ohm/km
- Ampacity: 225.0 A
4/0AWG
Nexans ref. 10028353
- Approximate weight: 1033 kg/km
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 15.27 mm
- Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km
- Ampacity: 260.0 A
250KCMIL
Nexans ref. 10028052
- Approximate weight: 1255 kg/km
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 17.54 mm
- Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km
- Ampacity: 290.0 A
300KCMIL
Nexans ref. 10028527
- Approximate weight: 1470 kg/km
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 18.81 mm
- Max. DC resistance of the conductor at 20°C: 0.118 Ohm/km
- Ampacity: 320.0 A
350KCMIL
Nexans ref. 10027661
- Approximate weight: 1720 kg/km
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 20.07 mm
- Max. DC resistance of the conductor at 20°C: 0.101 Ohm/km
- Ampacity: 350.0 A
400KCMIL
Nexans ref. 10031528
- Approximate weight: 1936 kg/km
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 21.12 mm
- Max. DC resistance of the conductor at 20°C: 0.088 Ohm/km
- Ampacity: 380.0 A
500KCMIL
Nexans ref. 10028156
- Approximate weight: 2407 kg/km
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 23.3 mm
- Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km
- Ampacity: 430.0 A
600KCMIL
Nexans ref. 10037056
- Approximate weight: 2995 kg/km
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 26.26 mm
- Max. DC resistance of the conductor at 20°C: 0.0593 Ohm/km
- Ampacity: 475.0 A
750KCMIL
Nexans ref. 10042935
- Approximate weight: 3663 kg/km
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 28.85 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Ampacity: 535.0 A
1000 KCMIL
Nexans ref. 10038855
- Approximate weight: 4901 kg/km
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 32.64 mm
- Max. DC resistance of the conductor at 20°C: 0.0355 Ohm/km
- Ampacity: 615.0 A
1250KCMIL
Nexans ref. 10042977
- Approximate weight: 6081 kg/km
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 36.62 mm
- Max. DC resistance of the conductor at 20°C: 0.028 Ohm/km
- Ampacity: 665.0 A
Description
Description
Standards
-
NationalNTC 3277
Application
Low voltage power distribution. Board connection, industrial, commercial and residential building wiring. Sizes 12AWG and larger are suitable for cable tray according to RETIE, article 20.3, j.
Construction
Conductor
Soft copper, concentric stranded, class B.
Insulation
Cross linked polyethylene XLPE, type XHHW-2. Flame retardant, UV resistant. Suitable for dry and wet locations, NTC 2050, Table 310-13.
Applicable Standards
- UL 44, NTC 3277
Certificate
RETIE N° 02476
Operationg Temperature
90°C
Operating Voltage
600V
Opcional
- Other insulation colors.
Testing Conditions
- Ampacity for 90°C conductor temperature, 30°C ambientent temperature. No more than three current carrying conductor in a duct or raceway. NTC 2050, Table 310-16.
- Data indicated in this table is subject to normal manufacturing tolerances.
Singlecore XHHW-2
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania