EXTRAFLEX

Products

1/0 AWG

Nexans ref. 10027318

  • Conductor diameter: 9.99 mm
  • Approximate weight: 605 kg/km
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 14.25 mm
  • Ampacity: 170.0 A
  • Max. DC resistance of the conductor at 20°C: 0.345 Ohm/km

 

10 AWG

Nexans ref. 10034884

  • Conductor diameter: 2.89 mm
  • Approximate weight: 57 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 4.48 mm
  • Ampacity: 40.0 A
  • Max. DC resistance of the conductor at 20°C: 3.41 Ohm/km

 

1000 KCMIL

Nexans ref. 10044812

  • Conductor diameter: 31.6 mm
  • Approximate weight: 4997 kg/km
  • Nominal insulation thickness: 2.79 mm
  • Nominal outer diameter: 37.38 mm
  • Ampacity: 615.0 A
  • Max. DC resistance of the conductor at 20°C: 0.037 Ohm/km

 

12 AWG

Nexans ref. 10027694

  • Conductor diameter: 2.31 mm
  • Approximate weight: 39 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.91 mm
  • Ampacity: 30.0 A
  • Max. DC resistance of the conductor at 20°C: 5.422 Ohm/km

 

14 AWG

Nexans ref. 10027693

  • Conductor diameter: 1.83 mm
  • Approximate weight: 27 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.42 mm
  • Ampacity: 25.0 A
  • Max. DC resistance of the conductor at 20°C: 8.616 Ohm/km

 

16 AWG

Nexans ref. 10027652

  • Conductor diameter: 1.47 mm
  • Approximate weight: 20 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.06 mm
  • Ampacity: 18.0 A
  • Max. DC resistance of the conductor at 20°C: 13.714 Ohm/km

 

2 AWG

Nexans ref. 10030120

  • Conductor diameter: 7.91 mm
  • Approximate weight: 372 kg/km
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 11.15 mm
  • Ampacity: 130.0 A
  • Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km

 

2/0 AWG

Nexans ref. 10027610

  • Conductor diameter: 11.27 mm
  • Approximate weight: 748 kg/km
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 15.53 mm
  • Ampacity: 195.0 A
  • Max. DC resistance of the conductor at 20°C: 0.277 Ohm/km

 

250 KCMIL

Nexans ref. 10028225

  • Conductor diameter: 15.6 mm
  • Approximate weight: 1329.47 kg/km
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 20.257 mm
  • Ampacity: 290.0 A
  • Max. DC resistance of the conductor at 20°C: 0.147 Ohm/km

 

3/0 AWG

Nexans ref. 10027845

  • Conductor diameter: 12.65 mm
  • Approximate weight: 920 kg/km
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 16.91 mm
  • Ampacity: 225.0 A
  • Max. DC resistance of the conductor at 20°C: 0.219 Ohm/km

 

300 KCMIL

Nexans ref. 10035307

  • Conductor diameter: 16.97 mm
  • Approximate weight: 1611 kg/km
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 21.99 mm
  • Ampacity: 320.0 A
  • Max. DC resistance of the conductor at 20°C: 0.123 Ohm/km

 

350 KCMIL

Nexans ref. 10027716

  • Conductor diameter: 18.49 mm
  • Approximate weight: 1771.8 kg/km
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 23.111 mm
  • Ampacity: 350.0 A
  • Max. DC resistance of the conductor at 20°C: 0.105 Ohm/km

 

4 AWG

Nexans ref. 10030119

  • Conductor diameter: 6.3 mm
  • Approximate weight: 247 kg/km
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 9.54 mm
  • Ampacity: 95.0 A
  • Max. DC resistance of the conductor at 20°C: 0.867 Ohm/km

 

4/0 AWG

Nexans ref. 10027165

  • Conductor diameter: 14.27 mm
  • Approximate weight: 1098.91 kg/km
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 18.19 mm
  • Ampacity: 260.0 A
  • Max. DC resistance of the conductor at 20°C: 0.174 Ohm/km

 

400 KCMIL

Nexans ref. 10032140

  • Conductor diameter: 19.82 mm
  • Approximate weight: 2091 kg/km
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 24.84 mm
  • Ampacity: 380.0 A
  • Max. DC resistance of the conductor at 20°C: 0.092 Ohm/km

 

500KCMIL

Nexans ref. 10027611

  • Conductor diameter: 21.7 mm
  • Approximate weight: 2499.46 kg/km
  • Nominal insulation thickness: 2.41 mm
  • Nominal outer diameter: 26.72 mm
  • Ampacity: 430.0 A
  • Max. DC resistance of the conductor at 20°C: 0.074 Ohm/km

 

6 AWG

Nexans ref. 10030118

  • Conductor diameter: 4.97 mm
  • Approximate weight: 165 kg/km
  • Nominal insulation thickness: 1.52 mm
  • Nominal outer diameter: 8.21 mm
  • Ampacity: 75.0 A
  • Max. DC resistance of the conductor at 20°C: 1.375 Ohm/km

 

750 KCMIL

Nexans ref. 10037652

  • Conductor diameter: 24.22 mm
  • Approximate weight: 3840 kg/km
  • Nominal insulation thickness: 2.79 mm
  • Nominal outer diameter: 30.0 mm
  • Ampacity: 535.0 A
  • Max. DC resistance of the conductor at 20°C: 0.049 Ohm/km

 

8 AWG

Nexans ref. 10030117

  • Conductor diameter: 3.65 mm
  • Approximate weight: 95 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 6.03 mm
  • Ampacity: 55.0 A
  • Max. DC resistance of the conductor at 20°C: 2.185 Ohm/km

 

Description

Description

Standards

  • Product
    UL 758

Application

Low voltage power distribution. Board conection and wiring in industrial installations which require high flexibility. Suitable for cable tray.

Construction

Conductor
Soft copper, flexible stranded.

Insulation
Polyvinyl Chloridre (PVC), flame retardant, heat, abrassion and wet resistant.

Applicable Standards

  • IEC 60502-1

Certificate

RETIE and NORMA N° 02752

Operating Temperature

105°C

Operating Voltage

0,6/1kV 

Marking

  • Insulation in black color.

Opcional

  • Other insulation colors.
  • Other sizes and packing are available upon request.

Ampacity Conditions

  • ​Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit or raceway. NTC 2050, Table 310.15(B)(16).
  • The data indicated in this table are subject to normal manufacturing tolerances.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Flexible Copper
Conductor shape
Compressed
Insulation
PVC

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Excellent

Usage characteristics

Usage characteristics

Maximum operating temperature
105 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
150 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close