INSTRUMENTATION TRAY CABLES 300/600V PVC
INSTRUMENTATION TRAY CABLES 300/600V PVC
Multi-conductor instrumentation cable made with PVC-insulated tinned copper conductors, general shielding and PVC outer jacket.
Read more2x16AWG
Nexans ref. 205665
- Conductor cross-section: 1.31 mm²
- Conductor cross-section (AWG/KCMIL): 16
- Conductor diameter: 1.464 mm
- Number of cores: 2
- Nominal outer diameter: 6.55 mm
- Approximate weight: 66.44 kg/km
- Max. DC resistance of the conductor at 20°C: 14.6 Ohm/km
- Minimum repeated bending diameter: 27 mm
3x16AWG
Nexans ref. 206537
- Conductor cross-section: 1.31 mm²
- Conductor cross-section (AWG/KCMIL): 16
- Conductor diameter: 1.464 mm
- Number of cores: 3
- Nominal outer diameter: 6.9 mm
- Approximate weight: 101.47 kg/km
- Max. DC resistance of the conductor at 20°C: 14.6 Ohm/km
- Minimum repeated bending diameter: 31 mm
4x16AWG
Nexans ref. 201235
- Conductor cross-section: 1.31 mm²
- Conductor cross-section (AWG/KCMIL): 16
- Conductor diameter: 1.464 mm
- Number of cores: 4
- Nominal outer diameter: 7.75 mm
- Approximate weight: 78.67 kg/km
- Max. DC resistance of the conductor at 20°C: 14.6 Ohm/km
- Minimum repeated bending diameter: 28 mm
2x18AWG
Nexans ref. 201220
- Conductor cross-section: 0.821 mm²
- Conductor cross-section (AWG/KCMIL): 18
- Conductor diameter: 1.161 mm
- Number of cores: 2
- Nominal outer diameter: 5.95 mm
- Approximate weight: 53.39 kg/km
- Max. DC resistance of the conductor at 20°C: 23.2 Ohm/km
- Minimum repeated bending diameter: 24 mm
3x18AWG
Nexans ref. 201222
- Conductor cross-section: 0.821 mm²
- Conductor cross-section (AWG/KCMIL): 18
- Conductor diameter: 1.161 mm
- Number of cores: 3
- Nominal outer diameter: 6.25 mm
- Approximate weight: 60.22 kg/km
- Max. DC resistance of the conductor at 20°C: 23.2 Ohm/km
- Minimum repeated bending diameter: 25 mm
4x18AWG
Nexans ref. 201224
- Conductor cross-section: 0.821 mm²
- Conductor cross-section (AWG/KCMIL): 18
- Conductor diameter: 1.161 mm
- Number of cores: 4
- Nominal outer diameter: 6.76 mm
- Approximate weight: 73.11 kg/km
- Max. DC resistance of the conductor at 20°C: 23.2 Ohm/km
- Minimum repeated bending diameter: 28 mm
7x18AWG
Nexans ref. 206535
- Conductor cross-section: 0.821 mm²
- Conductor cross-section (AWG/KCMIL): 18
- Conductor diameter: 1.161 mm
- Number of cores: 7
- Nominal outer diameter: 8.17 mm
- Approximate weight: 114.68 kg/km
- Max. DC resistance of the conductor at 20°C: 23.2 Ohm/km
- Minimum repeated bending diameter: 33 mm
Description
Description
Standards
-
ProductASTM B 33; ASTM B 8; UL 13; UL 2250
Application
Instrumentation cables are used in supervision and/or control systems. Handling low-power electrical signals, for transporting information to monitors on boards and in general for control systems.
Construction
Conductor
Tinned copper (CuSn) conductor class B.
Insulation
Thermoplastic compound in polyvinyl chloride (PVC), flame retardant (FR), resistant to abrasion, heat and humidity. Compound free of hazardous substances (RoHS).
Shielding
Formed by aluminized polyester tape with 100% coverage and drain conductor in tinned copper (CuSn).
Overall Jacket
External cover with thermoplastic compound in polyvinyl chloride (PVC), flame retardant, resistant to abrasion, moisture, for use in trays (TC), sunlight resistant (SR). Compound free of hazardous substances (RoHS).
Applicable Standards
- UL 2250
- NTC 5917
- UL 13
- MIL-W-16878
Certificate:
- RETIE
- CIDET N° 01669
Operating Temperature
105 °C.
Operating Voltage
300/600 V
Identification
- Conductors identification:
Two conductors: black-white.
Three conductors: black-white-red.
Four conductors: black-red-blue-orange.
Seven conductors: black-red-blue-orange-yellow-brown.
- Jacket identification:
Gray color with marking and sequential meter by meter.
Packaging Unit
Reels by 1000 m.
Optional:
- Flexible conductor.
- Low-smoke (LS) or halogen-free (HF FR) insulation.
- Insulation in polyvinyl chloride (PVC) with nylon.
- Armor in steel wires or interlocked steel.
- Low smoke emission (LS) and halogen-free (HF) jacket.
Ampacity Conditions
Values according to section 727.8 of the NEC and NTC 2050 Standard.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania