2/0 AWG

Description

Description

Application

Welding cables are used for extra-heavy duty and as power to the electrode of welding equipment, both in alternating and direct current.

They are also used in continuous service applications where flexibility is required in installation and/or operation.

Construction

Conductor

Flexible soft copper.

Insulation

Thermoplastic elastomer compound (TPE), flame retardant (FR), resistant to heat, abrasion and humidity; free of hazardous substances (RoHS).

Applicable Standards

NTC 6078

Certificate

RETIE N° 06628

Operating Temperature

105°C

Operating Voltage

600V

Marking

CENTELSA by NEXANS CABLE DE SOLDADURA Cu 105°C < Calibre AWG / Kcmil >  600 V TPE - HECHO EN COLOMBIA.

Ampacity Conditions

  • Ampacity 1:  To 90 °C conductor temperature, 30°C ambient temperature and a load factor of 100%. According to NTC 6078, Table B.5, Up to three current-carrying conductors in a conduit or directly buried.
  • Ampacity 2:  To 90 °C conductor temperature, 30°C ambient temperature and a load factor of 85%. According to NTC 6078, Table B.4, based on repeated 5-minute work cycles.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible
Conductor material
Soft copper
Conductor shape
Bunched Wires
Insulation
TPE

Dimensional characteristics

Dimensional characteristics

Approximate weight
683.33 kg/km
Conductor cross-section
67.4 mm²
Conductor diameter
10.83 mm
Nominal insulation thickness
2.03 mm
Nominal outer diameter
14.92 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Ampacity
195.0 A
Ampacity 90°C
357 A
Max. DC resistance of the conductor at 20°C
0.276 Ohm/km
Operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good
Mechanical resistance to impacts
UL 493

Usage characteristics

Usage characteristics

Flame retardant
NTC 3203 N°1080, VW-1 Flame Test
Max. conductor temperature in service
105 °C
RoHS compliant
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close