CABLES BAJO CONTENIDO DE HALÓGENOS LHFR-LS AL S8000 90°C
1/0AWG
Nexans ref. 209785
- Approximate weight: 246.7 kg/km
- Conductor cross-section: 53.5 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 12.71 mm
- Ampacity: 135.0 A
- Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km
2 AWG
Nexans ref. 209783
- Approximate weight: 153.86 kg/km
- Conductor cross-section: 33.6 mm²
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 9.97 mm
- Ampacity: 100.0 A
- Max. DC resistance of the conductor at 20°C: 0.875 Ohm/km
2/0 AWG
Nexans ref. 209786
- Approximate weight: 294.37 kg/km
- Conductor cross-section: 67.4 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 13.73 mm
- Ampacity: 150.0 A
- Max. DC resistance of the conductor at 20°C: 0.436 Ohm/km
250 kcmil
Nexans ref. 209789
- Approximate weight: 521.04 kg/km
- Conductor cross-section: 127 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 18.17 mm
- Ampacity: 230.0 A
- Max. DC resistance of the conductor at 20°C: 0.232 Ohm/km
3/0AWG
Nexans ref. 209787
- Approximate weight: 353.62 kg/km
- Conductor cross-section: 85 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 14.92 mm
- Ampacity: 175.0 A
- Max. DC resistance of the conductor at 20°C: 0.346 Ohm/km
300 kcmil
Nexans ref. 209790
- Approximate weight: 604.23 kg/km
- Conductor cross-section: 152 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 19.44 mm
- Ampacity: 260.0 A
- Max. DC resistance of the conductor at 20°C: 0.194 Ohm/km
350 kcmil
Nexans ref. 209791
- Approximate weight: 686.3 kg/km
- Conductor cross-section: 177 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 20.61 mm
- Ampacity: 280.0 A
- Max. DC resistance of the conductor at 20°C: 0.166 Ohm/km
4 AWG
Nexans ref. 209782
- Approximate weight: 109.07 kg/km
- Conductor cross-section: 21.2 mm²
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 8.57 mm
- Ampacity: 75.0 A
- Max. DC resistance of the conductor at 20°C: 1.39 Ohm/km
4/0 AWG
Nexans ref. 209788
- Approximate weight: 426.78 kg/km
- Conductor cross-section: 107 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 16.25 mm
- Ampacity: 205.0 A
- Max. DC resistance of the conductor at 20°C: 0.274 Ohm/km
400 kcmil
Nexans ref. 209792
- Approximate weight: 767.47 kg/km
- Conductor cross-section: 203 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 21.7 mm
- Ampacity: 305.0 A
- Max. DC resistance of the conductor at 20°C: 0.145 Ohm/km
500 kcmil
Nexans ref. 209793
- Approximate weight: 927.16 kg/km
- Conductor cross-section: 253 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 23.65 mm
- Ampacity: 350.0 A
- Max. DC resistance of the conductor at 20°C: 0.116 Ohm/km
6AWG
Nexans ref. 209781
- Approximate weight: 79.15 kg/km
- Conductor cross-section: 13.3 mm²
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 7.45 mm
- Ampacity: 55.0 A
- Max. DC resistance of the conductor at 20°C: 2.21 Ohm/km
Description
Description
Centelsa by Nexans Low-Halogen cables are part of the Nexans Fire Safety offer that allows you to protect people's lives, anticipate risks and secure assets in the event of fires.
Our Low-Halogen Cables do not spread fire, have low smoke emission, do not emit toxic gases and have a maximum operating temperature of 90°C.
Application
Cables for low voltage electrical energy distribution, installations in buildings, inside premises, control panels and electronic circuits. Suitable for places with a high concentration of people, where low-halogen conductors and low smoke emission are required, which in the event of a fire will not generate toxic or corrosive gases that may affect the health of people and the condition of equipment and circuits electronics. The cables can be used for installations mentioned in NTC 2050 Article 310.
Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.
Construction
Conductor
S8000 Aluminium
Insulation
Low halogen, flame retardant and low smoke emission opaque, dense, toxic and corrosive thermoplastic compound.
Applicable Standards
NTC 6182
Certificate
RETIE N° 07511 / RETIE N° 05915
Operating Temperature
90°C, obtaining greater current capacity compared to a 75°C cable, more efficient electrical design.
Operating Voltage
600V
Marking
CENTELSA by NEXANS < Calibre AWG / Kcmil > AL AA8000 LHFR-LS 600 V 90°C CT - HECHO EN COLOMBIA [M].
Ampacity Conditions
- Ampacity to 90 °C conductor temperature, 30°C ambient temperature. No more than three current carrying condutores in a duct or pipe. According to NTC 2050, Table 310.15(B)(16) NTC 2050.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Fire Safety - NEXANS
LHFR-LS Cables - Low Halogen
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania