CABLE XHHW-2 Cu 90°C 600 V CT

Products

14AWG

Nexans ref.

  • Approximate weight: 31 kg/km
  • Conductor cross-section: 2.08 mm²
  • Conductor cross-section (AWG/KCMIL): 14
  • Conductor diameter: 1.79 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.39 mm
  • Ampacity: 25.0 A
  • Max. DC resistance of the conductor at 20°C: 8.629 Ohm/km

 

12AWG

Nexans ref. 207973

  • Approximate weight: 38.64 kg/km
  • Conductor cross-section: 3.31 mm²
  • Conductor cross-section (AWG/KCMIL): 12
  • Conductor diameter: 2.26 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 3.86 mm
  • Ampacity: 30.0 A
  • Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km

 

10AWG

Nexans ref. 207974

  • Approximate weight: 57.65 kg/km
  • Conductor cross-section: 5.26 mm²
  • Conductor cross-section (AWG/KCMIL): 10
  • Conductor diameter: 2.85 mm
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 4.45 mm
  • Ampacity: 40.0 A
  • Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km

 

8AWG

Nexans ref. 207958

  • Approximate weight: 93.21 kg/km
  • Conductor cross-section: 8.37 mm²
  • Conductor cross-section (AWG/KCMIL): 8
  • Conductor diameter: 3.39 mm
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 5.77 mm
  • Ampacity: 55.0 A
  • Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km

 

6AWG

Nexans ref. 207959

  • Approximate weight: 142.72 kg/km
  • Conductor cross-section: 13.3 mm²
  • Conductor cross-section (AWG/KCMIL): 6
  • Conductor diameter: 4.28 mm
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 6.66 mm
  • Ampacity: 75.0 A
  • Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km

 

4AWG

Nexans ref. 207960

  • Approximate weight: 217.05 kg/km
  • Conductor cross-section: 21.2 mm²
  • Conductor cross-section (AWG/KCMIL): 4
  • Conductor diameter: 5.4 mm
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 7.78 mm
  • Ampacity: 95.0 A
  • Max. DC resistance of the conductor at 20°C: 0.847 Ohm/km

 

2AWG

Nexans ref. 208169

  • Approximate weight: 334.94 kg/km
  • Conductor cross-section: 33.6 mm²
  • Conductor cross-section (AWG/KCMIL): 2
  • Conductor diameter: 6.81 mm
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 9.19 mm
  • Ampacity: 130.0 A
  • Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km

 

1/0AWG

Nexans ref. 208168

  • Approximate weight: 529.77 kg/km
  • Conductor cross-section: 53.5 mm²
  • Conductor cross-section (AWG/KCMIL): 1/0
  • Conductor diameter: 8.93 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer diameter: 11.85 mm
  • Ampacity: 170.0 A
  • Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km

 

2/0AWG

Nexans ref. 208167

  • Approximate weight: 666.48 kg/km
  • Conductor cross-section: 67.4 mm²
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor diameter: 10.02 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer diameter: 12.94 mm
  • Ampacity: 195.0 A
  • Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km

 

4/0AWG

Nexans ref. 208166

  • Approximate weight: 1034.31 kg/km
  • Conductor cross-section: 107 mm²
  • Conductor cross-section (AWG/KCMIL): 4/0
  • Conductor diameter: 12.64 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer diameter: 15.56 mm
  • Ampacity: 260.0 A
  • Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km

 

250kcmil

Nexans ref. 207961

  • Approximate weight: 1223.9 kg/km
  • Conductor cross-section: 127 mm²
  • Conductor cross-section (AWG/KCMIL): 250
  • Conductor diameter: 13.25 mm
  • Nominal insulation thickness: 1.65 mm
  • Nominal outer diameter: 16.69 mm
  • Ampacity: 290.0 A
  • Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km

 

300kcmil

Nexans ref. 207962

  • Approximate weight: 1464.26 kg/km
  • Conductor cross-section: 152 mm²
  • Conductor cross-section (AWG/KCMIL): 300
  • Conductor diameter: 14.52 mm
  • Nominal insulation thickness: 1.65 mm
  • Nominal outer diameter: 17.96 mm
  • Ampacity: 320.0 A
  • Max. DC resistance of the conductor at 20°C: 0.118 Ohm/km

 

350kcmil

Nexans ref. 207963

  • Approximate weight: 1699.38 kg/km
  • Conductor cross-section: 177 mm²
  • Conductor cross-section (AWG/KCMIL): 350
  • Conductor diameter: 15.68 mm
  • Nominal insulation thickness: 1.65 mm
  • Nominal outer diameter: 19.12 mm
  • Ampacity: 350.0 A
  • Max. DC resistance of the conductor at 20°C: 0.101 Ohm/km

 

500kcmil

Nexans ref. 207965

  • Approximate weight: 2393.23 kg/km
  • Conductor cross-section: 253 mm²
  • Conductor cross-section (AWG/KCMIL): 500
  • Conductor diameter: 18.74 mm
  • Nominal insulation thickness: 1.65 mm
  • Nominal outer diameter: 22.18 mm
  • Ampacity: 430.0 A
  • Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km

 

750kcmil

Nexans ref. 208723

  • Approximate weight: 3616.68 kg/km
  • Conductor cross-section: 380 mm²
  • Conductor cross-section (AWG/KCMIL): 750
  • Conductor diameter: 23.1 mm
  • Nominal insulation thickness: 2.03 mm
  • Nominal outer diameter: 27.28 mm
  • Ampacity: 535.0 A
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km

 

Description

Description

Standards

  • Product
    UL 44

Application

CENTELSA by Nexans XHHW–2 cables are used for low voltage electrical power distribution, in the connection of board, motors and wiring in buildings.

Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.

Construction

Conductor

Soft copper conductor, stranded class B.

Insulation

Cross-linked polyethylene (XLPE) insulation, flame retardant (FR), resistant to abrasion, heat and humidity.

Applicable Standards

UL 44

Certificate

RETIE N° 05603

Operating Temperature

90°C

Operating Voltage

600 V

Identification

Black color insulation.

Sequential length meter by meter with return to zero.

Packaging Units

Wooden reels of 1000 m. Other packaging units available upon request.

Marking

CENTELSA by NEXANS < Calibre AWG / Kcmil >  Cu XHHW-2 600 V 90°C CT SR- HECHO EN COLOMBIA [M].

Ampacity Conditions

  • Ampacity to 90 °C conductor temperature, 30°C ambient temperature. No more than three current carrying condutors in a duct or pipe. According to NTC 2050, Table 310.15(B)(16).

 

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Conductor flexibility
Class B
Insulation
Cross-linked polyethylene

Electrical characteristics

Electrical characteristics

Operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
Good

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C
RoHS compliant
Yes
U.V resistance
Yes (720 hours)
Fire retardant
Method 1 - Vertical Tray (UL 2556/9.6)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close