CABLE XHHW-2 Cu 90°C 600 V CT
CABLE XHHW-2 Cu 90°C 600 V CT
Soft tempered copper conductor, insulated in XLPE compound.
Read more14AWG
Nexans ref.
- Approximate weight: 31 kg/km
- Conductor cross-section: 2.08 mm²
- Conductor cross-section (AWG/KCMIL): 14
- Conductor diameter: 1.79 mm
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 3.39 mm
- Ampacity: 25.0 A
- Max. DC resistance of the conductor at 20°C: 8.629 Ohm/km
12AWG
Nexans ref. 207973
- Approximate weight: 38.64 kg/km
- Conductor cross-section: 3.31 mm²
- Conductor cross-section (AWG/KCMIL): 12
- Conductor diameter: 2.26 mm
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 3.86 mm
- Ampacity: 30.0 A
- Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km
10AWG
Nexans ref. 207974
- Approximate weight: 57.65 kg/km
- Conductor cross-section: 5.26 mm²
- Conductor cross-section (AWG/KCMIL): 10
- Conductor diameter: 2.85 mm
- Nominal insulation thickness: 0.76 mm
- Nominal outer diameter: 4.45 mm
- Ampacity: 40.0 A
- Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km
8AWG
Nexans ref. 207958
- Approximate weight: 93.21 kg/km
- Conductor cross-section: 8.37 mm²
- Conductor cross-section (AWG/KCMIL): 8
- Conductor diameter: 3.39 mm
- Nominal insulation thickness: 1.14 mm
- Nominal outer diameter: 5.77 mm
- Ampacity: 55.0 A
- Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km
6AWG
Nexans ref. 207959
- Approximate weight: 142.72 kg/km
- Conductor cross-section: 13.3 mm²
- Conductor cross-section (AWG/KCMIL): 6
- Conductor diameter: 4.28 mm
- Nominal insulation thickness: 1.14 mm
- Nominal outer diameter: 6.66 mm
- Ampacity: 75.0 A
- Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km
4AWG
Nexans ref. 207960
- Approximate weight: 217.05 kg/km
- Conductor cross-section: 21.2 mm²
- Conductor cross-section (AWG/KCMIL): 4
- Conductor diameter: 5.4 mm
- Nominal insulation thickness: 1.14 mm
- Nominal outer diameter: 7.78 mm
- Ampacity: 95.0 A
- Max. DC resistance of the conductor at 20°C: 0.847 Ohm/km
2AWG
Nexans ref. 208169
- Approximate weight: 334.94 kg/km
- Conductor cross-section: 33.6 mm²
- Conductor cross-section (AWG/KCMIL): 2
- Conductor diameter: 6.81 mm
- Nominal insulation thickness: 1.14 mm
- Nominal outer diameter: 9.19 mm
- Ampacity: 130.0 A
- Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
1/0AWG
Nexans ref. 208168
- Approximate weight: 529.77 kg/km
- Conductor cross-section: 53.5 mm²
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor diameter: 8.93 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 11.85 mm
- Ampacity: 170.0 A
- Max. DC resistance of the conductor at 20°C: 0.335 Ohm/km
2/0AWG
Nexans ref. 208167
- Approximate weight: 666.48 kg/km
- Conductor cross-section: 67.4 mm²
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor diameter: 10.02 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 12.94 mm
- Ampacity: 195.0 A
- Max. DC resistance of the conductor at 20°C: 0.266 Ohm/km
4/0AWG
Nexans ref. 208166
- Approximate weight: 1034.31 kg/km
- Conductor cross-section: 107 mm²
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor diameter: 12.64 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer diameter: 15.56 mm
- Ampacity: 260.0 A
- Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km
250kcmil
Nexans ref. 207961
- Approximate weight: 1223.9 kg/km
- Conductor cross-section: 127 mm²
- Conductor cross-section (AWG/KCMIL): 250
- Conductor diameter: 13.25 mm
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 16.69 mm
- Ampacity: 290.0 A
- Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km
300kcmil
Nexans ref. 207962
- Approximate weight: 1464.26 kg/km
- Conductor cross-section: 152 mm²
- Conductor cross-section (AWG/KCMIL): 300
- Conductor diameter: 14.52 mm
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 17.96 mm
- Ampacity: 320.0 A
- Max. DC resistance of the conductor at 20°C: 0.118 Ohm/km
350kcmil
Nexans ref. 207963
- Approximate weight: 1699.38 kg/km
- Conductor cross-section: 177 mm²
- Conductor cross-section (AWG/KCMIL): 350
- Conductor diameter: 15.68 mm
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 19.12 mm
- Ampacity: 350.0 A
- Max. DC resistance of the conductor at 20°C: 0.101 Ohm/km
500kcmil
Nexans ref. 207965
- Approximate weight: 2393.23 kg/km
- Conductor cross-section: 253 mm²
- Conductor cross-section (AWG/KCMIL): 500
- Conductor diameter: 18.74 mm
- Nominal insulation thickness: 1.65 mm
- Nominal outer diameter: 22.18 mm
- Ampacity: 430.0 A
- Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km
750kcmil
Nexans ref. 208723
- Approximate weight: 3616.68 kg/km
- Conductor cross-section: 380 mm²
- Conductor cross-section (AWG/KCMIL): 750
- Conductor diameter: 23.1 mm
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 27.28 mm
- Ampacity: 535.0 A
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
Description
Description
Standards
-
ProductUL 44
Application
CENTELSA XHHW–2 cables are used for low voltage electrical power distribution, in the connection of board, motors and wiring in buildings.
Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.
Construction
Conductor
Soft copper conductor, stranded class B.
Insulation
Cross-linked polyethylene (XLPE) insulation, flame retardant (FR), resistant to abrasion, heat and humidity.
Applicable Standards
UL 44
Certificate
RETIE N° 05603
Operating Temperature
90°C
Operating Voltage
600 V
Identification
Black color insulation.
Sequential length meter by meter with return to zero.
Packaging Units
Wooden reels of 1000 m. Other packaging units available upon request.
Marking
CENTELSA by NEXANS < Calibre AWG / Kcmil > Cu XHHW-2 600 V 90°C CT SR- HECHO EN COLOMBIA [M].
Ampacity Conditions
- Ampacity to 90 °C conductor temperature, 30°C ambient temperature. No more than three current carrying condutores in a duct or pipe. According to NTC 2050, Table 310.15(B)(16).
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania