CABLE MULTIFLEX TC 600V 18 AWG - 10 AWG
CABLE MULTIFLEX TC 600V 18 AWG - 10 AWG
Multiconductor cable of two, three or four soft copper flexible conductors.
Read more2x10AWG
Nexans ref. 213917
- Conductor cross-section: 5.26 mm²
- Approximate weight: 193.24 kg/km
- Conductor diameter: 3.05 mm
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 10.38 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 3.478 Ohm/km
- Perm current rating in air 30°C: 55 A
- Perm current rating in duct/buried 30°C: 40 A
- Ampacity: 40.0 A
3x10AWG
Nexans ref. 213918
- Conductor cross-section: 5.27 mm²
- Approximate weight: 244.34 kg/km
- Conductor diameter: 3.05 mm
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 11.06 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 3.478 Ohm/km
- Perm current rating in air 30°C: 55 A
- Perm current rating in duct/buried 30°C: 40 A
- Ampacity: 40.0 A
4x10AWG
Nexans ref. 213919
- Conductor cross-section: 5.28 mm²
- Approximate weight: 305.18 kg/km
- Conductor diameter: 3.05 mm
- Nominal insulation thickness: 0.51 mm
- Nominal outer diameter: 12.2 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 3.478 Ohm/km
- Perm current rating in air 30°C: 55 A
- Perm current rating in duct/buried 30°C: 40 A
- Ampacity: 40.0 A
4x12AWG
Nexans ref. 213922
- Conductor cross-section: 3.31 mm²
- Approximate weight: 199.86 kg/km
- Conductor diameter: 2.43 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 10.03 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 5.528 Ohm/km
- Perm current rating in air 30°C: 40 A
- Perm current rating in duct/buried 30°C: 30 A
- Ampacity: 30.0 A
2x12AWG
Nexans ref. 213920
- Conductor cross-section: 3.31 mm²
- Approximate weight: 128.23 kg/km
- Conductor diameter: 2.43 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 8.58 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 5.528 Ohm/km
- Perm current rating in air 30°C: 40 A
- Perm current rating in duct/buried 30°C: 30 A
- Ampacity: 30.0 A
3x12AWG
Nexans ref. 213921
- Conductor cross-section: 3.31 mm²
- Approximate weight: 160.83 kg/km
- Conductor diameter: 2.43 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 9.12 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 5.528 Ohm/km
- Perm current rating in air 30°C: 40 A
- Perm current rating in duct/buried 30°C: 30 A
- Ampacity: 30.0 A
4x14AWG
Nexans ref. 213925
- Conductor cross-section: 2.08 mm²
- Approximate weight: 143.6 kg/km
- Conductor diameter: 1.958 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 8.89 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 8.788 Ohm/km
- Perm current rating in air 30°C: 35 A
- Perm current rating in duct/buried 30°C: 25 A
- Ampacity: 25.0 A
2x14AWG
Nexans ref. 213923
- Conductor cross-section: 2.08 mm²
- Approximate weight: 94.55 kg/km
- Conductor diameter: 1.958 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 7.64 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 8.788 Ohm/km
- Perm current rating in air 30°C: 35 A
- Perm current rating in duct/buried 30°C: 25 A
- Ampacity: 25.0 A
3x14AWG
Nexans ref. 213924
- Conductor cross-section: 2.08 mm²
- Approximate weight: 116.6 kg/km
- Conductor diameter: 1.958 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 8.11 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 8.788 Ohm/km
- Perm current rating in air 30°C: 35 A
- Perm current rating in duct/buried 30°C: 25 A
- Ampacity: 25.0 A
2x16AWG
Nexans ref. 213926
- Conductor cross-section: 1.31 mm²
- Approximate weight: 70.37 kg/km
- Conductor diameter: 1.54 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 6.8 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 13.988 Ohm/km
- Perm current rating in air 30°C: 24 A
- Perm current rating in duct/buried 30°C: 18 A
- Ampacity: 18.0 A
3x16AWG
Nexans ref. 213927
- Conductor cross-section: 1.32 mm²
- Approximate weight: 85.35 kg/km
- Conductor diameter: 1.54 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 7.2 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 13.988 Ohm/km
- Perm current rating in air 30°C: 24 A
- Perm current rating in duct/buried 30°C: 18 A
- Ampacity: 18.0 A
4x16AWG
Nexans ref. 213928
- Conductor cross-section: 1.33 mm²
- Approximate weight: 104.17 kg/km
- Conductor diameter: 1.54 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 7.88 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 13.988 Ohm/km
- Perm current rating in air 30°C: 24 A
- Perm current rating in duct/buried 30°C: 18 A
- Ampacity: 18.0 A
2x18AWG
Nexans ref. 213929
- Conductor cross-section: 0.82 mm²
- Approximate weight: 53.93 kg/km
- Conductor diameter: 1.214 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 6.14 mm
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 22.231 Ohm/km
- Perm current rating in air 30°C: 18 A
- Perm current rating in duct/buried 30°C: 14 A
- Ampacity: 14.0 A
3x18AWG
Nexans ref. 213930
- Conductor cross-section: 0.82 mm²
- Approximate weight: 64.25 kg/km
- Conductor diameter: 1.214 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 6.49 mm
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 22.231 Ohm/km
- Perm current rating in air 30°C: 18 A
- Perm current rating in duct/buried 30°C: 14 A
- Ampacity: 14.0 A
4x18AWG
Nexans ref. 213931
- Conductor cross-section: 0.82 mm²
- Approximate weight: 77.59 kg/km
- Conductor diameter: 1.214 mm
- Nominal insulation thickness: 0.38 mm
- Nominal outer diameter: 7.08 mm
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 22.231 Ohm/km
- Perm current rating in air 30°C: 18 A
- Perm current rating in duct/buried 30°C: 14 A
- Ampacity: 14.0 A
Description
Description
Standards
-
ProductUL 1277; UL 66; UL 83
Application
Light duty cable used as a service cord for connection of portable tools and extension of appliances, in open installations and portable extensions with terminals. It can be used as a control cable where electrostatic shielding is not required.
Suitable for low voltage electrical power distribution, to be installed in sumps, installation in ducts and gutters, connection of boards and wiring in industrial or commercial buildings, for direct burial with light traffic, for installations in cable trays in dry, moisture, wet environments and outdoors. It can be used as a feeder cable for submersible pumps in water.
Note: Any other application or use not described above is considered prohibited.
Construction
Conductor
Extra-flexible soft copper conductors.
Insulation
Thermoplastic compound in polyvinyl chloride (PVC), flame retardant, fire retardant (FR), resistant to abrasion, heat and dry, moisture and wet environments. Compound free of hazardous substances (RoHS).
Individual Jacket
A Nylon cover resistant to contact with oils and petroleum derivatives such as gasoline is applied over the insulation.
Overall Jacket
External cover with thermoplastic compound in polyvinyl chloride (PVC), flame retardant, resistant to abrasion, moisture, impact (ER), sunlight resistant (SR). Compound free of hazardous substances (RoHS).
Applicable Standards
UL 1277
Certificate
CIDET No 06275
CIDET No 01668
Operating Temperature
90°C in dry, moisture and wet places.
Operating Voltage
600V
Identification
- Conductors identification:
Two conductors: black-white.
Three conductors: black-white-green.
Four conductors: black-white-red-green.
Five conductors: yellow-blue-red-white-green.
- Jacket identification:
Trace color according to the number of conductors and conductor size.
Ampacity Conditions
(*) Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit, raceway or directly buried. NTC 2050, Table 310.15(B)(16).
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Discover: NEXANS MULTIFLEX
Innovation Nexans Multiflex
Nexans Multiflex Gauges Identification
Nexans Multiflex Benefits
Nexans Multiflex Innovative Characteristics
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania