- Markets
- Catalogue
- Services and solutions
- Company
- Newsroom
- Tools & Resources
- Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
CABLE RHH/RHW-2/USE-2 AA8000 90°C 600 V SR
CABLE RHH/RHW-2/USE-2 AA8000 90°C 600 V SR
8000 series aluminum alloy conductor, insulated in XLPE compound.
Read more6AWG
Nexans ref. 204154
- Approximate weight: 65.64 kg/km
- Conductor cross-section: 13.3 mm²
- Conductor cross-section (AWG/KCMIL): 6
- Conductor diameter: 4.29 mm
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 7.45 mm
- Ampacity: 55.0 A
- Max. DC resistance of the conductor at 20°C: 2.212 Ohm/km
4AWG
Nexans ref. 204155
- Approximate weight: 92.67 kg/km
- Conductor cross-section: 21.2 mm²
- Conductor cross-section (AWG/KCMIL): 4
- Conductor diameter: 5.41 mm
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 8.57 mm
- Ampacity: 75.0 A
- Max. DC resistance of the conductor at 20°C: 1.39 Ohm/km
2AWG
Nexans ref. 204156
- Approximate weight: 133.69 kg/km
- Conductor cross-section: 33.6 mm²
- Conductor cross-section (AWG/KCMIL): 2
- Conductor diameter: 6.81 mm
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 9.97 mm
- Ampacity: 100.0 A
- Max. DC resistance of the conductor at 20°C: 0.875 Ohm/km
1/0AWG
Nexans ref. 204158
- Approximate weight: 214.04 kg/km
- Conductor cross-section: 53.5 mm²
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor diameter: 8.53 mm
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 12.71 mm
- Ampacity: 135.0 A
- Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km
2/0AWG
Nexans ref. 204159
- Approximate weight: 258.21 kg/km
- Conductor cross-section: 67.4 mm²
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor diameter: 9.55 mm
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 13.73 mm
- Ampacity: 150.0 A
- Max. DC resistance of the conductor at 20°C: 0.436 Ohm/km
4/0AWG
Nexans ref. 204160
- Approximate weight: 381.75 kg/km
- Conductor cross-section: 107 mm²
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor diameter: 12.07 mm
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 16.25 mm
- Ampacity: 205.0 A
- Max. DC resistance of the conductor at 20°C: 0.274 Ohm/km
250kcmil
Nexans ref. 204161
- Approximate weight: 462.76 kg/km
- Conductor cross-section: 127 mm²
- Conductor cross-section (AWG/KCMIL): 250
- Conductor diameter: 13.21 mm
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 18.17 mm
- Ampacity: 230.0 A
- Max. DC resistance of the conductor at 20°C: 0.232 Ohm/km
300kcmil
Nexans ref. 207074
- Approximate weight: 540.64 kg/km
- Conductor cross-section: 152 mm²
- Conductor cross-section (AWG/KCMIL): 300
- Conductor diameter: 14.48 mm
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 19.44 mm
- Ampacity: 260.0 A
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
350kcmil
Nexans ref. 204162
- Approximate weight: 617.74 kg/km
- Conductor cross-section: 177 mm²
- Conductor cross-section (AWG/KCMIL): 350
- Conductor diameter: 15.65 mm
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 20.61 mm
- Ampacity: 280.0 A
- Max. DC resistance of the conductor at 20°C: 0.166 Ohm/km
500kcmil
Nexans ref. 209711
- Approximate weight: 845.01 kg/km
- Conductor cross-section: 253 mm²
- Conductor cross-section (AWG/KCMIL): 500
- Conductor diameter: 18.69 mm
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 23.65 mm
- Ampacity: 350.0 A
- Max. DC resistance of the conductor at 20°C: 0.116 Ohm/km
Description
Description
Standards
-
ProductUL 44
Application
CENTELSA by Nexans RHH/RHW-2/USE-2 cables are used for wiring power circuits in commercial, residential and industrial installations. Suitable for use as underground connections and even direct burial under the installation conditions suggested in NTC 4564 / UL 854. Installation in ducts, pipes and switchboards.
Construction
Conductor
8000 series aluminum alloy, stranded class B.
Insulation
Cross-linked polyethylene (XLPE) insulation, sunlight resistant (SR), flame retardant (FR), resistant to abrasion, heat and humidity.
Applicable Standards
UL 44
Certificate
RETIE
CIDET N° 05603
Operating Temperature
90°C
Operating Voltage
600 V
Identification
Black color insulation.
Sequential length meter by meter with return to zero.
Packaging Units
Wooden reels of 1000 m. Other packaging units available upon request.
Optional:
• CT marking, installation on cable trays according to RETIE article 20.3, literal J.
• Halogen-free (HF) and low smoke emission (LS).
• Operating voltage: 2000 V for RHH/RHW-2
Marking
CENTELSA by NEXANS < Calibre AWG / Kcmil > AA8000 AL RHH OR RHW-2 OR USE-2 600 V 90°C SR - HECHO EN COLOMBIA [M]
Ampacity Conditions
- Ampacity to 90 °C conductor temperature, 30°C ambient temperature. No more than three current carrying condutors in a duct or pipe. According to NTC 2050, Table 310.15(B)(16).
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania