Service Entrance Cable Cu 600V (Trebol)

Products

3x2+4AWG

Nexans ref. 10011187

  • Conductor cross-section: 33.6 mm²
  • Approximate weight: 1443.21 kg/km
  • Nominal outer diameter: 26.08 mm
  • Max. DC resistance of the conductor at 20°C: 0.543 Ohm/km
  • Ampacity: 115.0 A

 

3x6+8AWG

Nexans ref. 10011189

  • Conductor cross-section: 13.3 mm²
  • Approximate weight: 628.04 kg/km
  • Nominal outer diameter: 18.94 mm
  • Max. DC resistance of the conductor at 20°C: 1.373 Ohm/km
  • Ampacity: 65.0 A

 

3x8+10AWG

Nexans ref. 10012289

  • Conductor cross-section: 8.37 mm²
  • Approximate weight: 454.92 kg/km
  • Nominal outer diameter: 17.12 mm
  • Max. DC resistance of the conductor at 20°C: 2.185 Ohm/km
  • Ampacity: 50.0 A

 

Description

Description

Standards

  • Product
    ASTM B 3; ASTM B 8; ICEA S-95-658; NTC 1099-1
  • National
    NTC 307; NTC 359

Application

Low voltage distribution systems, from secondary distribution grid to user equipment measurement.

 

Construction

Phase Conductor
Soft copper conductors, concentric stranded, class B.

Insulation
Polyethylene (PE).

Jacket
Polyvinil Chloridre (PVC).

Applicable Standards

  • NTC 1099-1, ICEA S-95-658
  • NTC 307, ASTM B8
  • NTC 359, ASTM B3

Certificate
RETIE and NORMA N° 02485

Operating Temperature
75°C
 

Operating Voltage
600V.

 

Marking

  • Phase conductors color: Yellow / Blue / Red.
  • Neutral conductor color: White.

Testing Conditions

  • Ampacity for ambient temperature 30°C, conductor temperature 90°C, no more than three carriyng current conductors in a duct. 
  • Data indicated in this table are subject to normal manufacturing tolerances.

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulation
PE
Conductor flexibility
Class B

Dimensional characteristics

Dimensional characteristics

Nominal insulation thickness
1.14 mm
Number of cores
3

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
600 V

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
High

Usage characteristics

Usage characteristics

Weather resistance
Yes
Maximum operating temperature
75 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close