POWER CABLES Cu 90°C XHHW-2 600V PVC TC

Products

2x12 AWG

Nexans ref. 209774

  • Conductor shape: Compressed
  • Conductor diameter: 2.26 mm
  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 159 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 10.1 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 5.42 Ohm/km
  • Ampacity: 30.0 A

 

3x12 AWG

Nexans ref. 208930

  • Conductor shape: Compressed
  • Conductor diameter: 2.26 mm
  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 195 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 10.7 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 5.42 Ohm/km
  • Ampacity: 30.0 A

 

4x12 AWG

Nexans ref. 210249

  • Conductor shape: Compressed
  • Conductor diameter: 2.26 mm
  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 240 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 11.7 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 5.42 Ohm/km
  • Ampacity: 30.0 A

 

2x10 AWG

Nexans ref. 208554

  • Conductor shape: Compressed
  • Conductor diameter: 2.85 mm
  • Conductor cross-section: 5.26 mm²
  • Approximate weight: 215 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 11.28 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 3.41 Ohm/km
  • Ampacity: 40.0 A

 

3x10 AWG

Nexans ref. 208931

  • Conductor shape: Compressed
  • Conductor diameter: 2.85 mm
  • Conductor cross-section: 5.26 mm²
  • Approximate weight: 269 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 11.97 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 3.41 Ohm/km
  • Ampacity: 40.0 A

 

4x10AWG

Nexans ref. 208385

  • Conductor shape: Compressed
  • Conductor diameter: 2.85 mm
  • Conductor cross-section: 5.26 mm²
  • Approximate weight: 333 kg/km
  • Nominal insulation thickness: 0.76 mm
  • Nominal outer diameter: 13.12 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 3.41 Ohm/km
  • Ampacity: 40.0 A

 

2x8 AWG

Nexans ref. 207928

  • Conductor shape: Compact round
  • Conductor diameter: 3.39 mm
  • Conductor cross-section: 8.37 mm²
  • Approximate weight: 356 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 14.7 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 2.144 Ohm/km
  • Ampacity: 55.0 A

 

3x8 AWG

Nexans ref. 207927

  • Conductor shape: Compact round
  • Conductor diameter: 3.39 mm
  • Conductor cross-section: 8.37 mm²
  • Approximate weight: 443 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 15.59 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 2.144 Ohm/km
  • Ampacity: 55.0 A

 

4x8 AWG

Nexans ref. 208386

  • Conductor shape: Compact round
  • Conductor diameter: 3.39 mm
  • Conductor cross-section: 8.37 mm²
  • Approximate weight: 547 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 17.09 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 2.144 Ohm/km
  • Ampacity: 55.0 A

 

2x6 AWG

Nexans ref. 207926

  • Conductor shape: Compact round
  • Conductor diameter: 4.28 mm
  • Conductor cross-section: 13.3 mm²
  • Approximate weight: 494 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 16.48 mm
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 1.348 Ohm/km
  • Ampacity: 75.0 A

 

3x6 AWG

Nexans ref. 207925

  • Conductor shape: Compact round
  • Conductor diameter: 4.28 mm
  • Conductor cross-section: 13.3 mm²
  • Approximate weight: 627 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 17.51 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 1.348 Ohm/km
  • Ampacity: 75.0 A

 

4x6 AWG

Nexans ref. 208933

  • Conductor shape: Compact round
  • Conductor diameter: 4.28 mm
  • Conductor cross-section: 13.3 mm²
  • Approximate weight: 783 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 19.24 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 1.348 Ohm/km
  • Ampacity: 75.0 A

 

3x4 AWG

Nexans ref. 208772

  • Conductor shape: Compact round
  • Conductor diameter: 5.4 mm
  • Conductor cross-section: 21.2 mm²
  • Approximate weight: 900 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 19.93 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.848 Ohm/km
  • Ampacity: 95.0 A

 

4x4 AWG

Nexans ref. 208934

  • Conductor shape: Compact round
  • Conductor diameter: 5.4 mm
  • Conductor cross-section: 21.2 mm²
  • Approximate weight: 1184 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 22.96 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.848 Ohm/km
  • Ampacity: 95.0 A

 

3x2AWG

Nexans ref. 209484

  • Conductor shape: Compact round
  • Conductor diameter: 6.81 mm
  • Conductor cross-section: 33.63 mm²
  • Approximate weight: 1377 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 23.98 mm
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.533 Ohm/km
  • Ampacity: 130.0 A

 

4x2 AWG

Nexans ref. 210216

  • Conductor shape: Compact round
  • Conductor diameter: 6.81 mm
  • Conductor cross-section: 33.63 mm²
  • Approximate weight: 1738 kg/km
  • Nominal insulation thickness: 1.14 mm
  • Nominal outer diameter: 26.37 mm
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.533 Ohm/km
  • Ampacity: 130.0 A

 

Description

Description

Standards

  • Product
    ASTM B 496; ASTM B 8; UL 1277; UL 44

APPLICATION

XHHW-2 power cables are used in industrial facilities, for low voltage electrical energy distribution. Installation in dry or wet locations, in sumps, pipelines or direct burial, in places where there is no heavy traffic. Suitable for use in tray (TC) with external cover (jacket) resistant to UV rays (SR).

CONSTRUCTION

Conductor

Soft copper, concentric stranded class B.

Insulation

Individually insulated conductors with XLPE compound type XHHW-2.

Jacket

Polyvinyl Chloride PVC, flame retardant, resistant to abrasion, heat and humidity.

 

Applicable Standards

  • UL 44, NTC 3277
  • UL 1277, NTC 5916

Certificate

  • RETIE
  • CIDET N° 01668
  • CIDET N° 04592

Operating Temperature

90 °C

Operating Voltage

600 V

Identification

Individually insulated conductors identified with numbers + black color base. Jacket in black color with marking and sequential meter by meter.

Packaging Unit

Reels by 500 m or 1000 m

Optional

  • Individually insulated conductors with PVC compound type THHW-2.
  • Other identification methods (Colored insulated conductors or green grounding).
  • Jacket in polyethylene (PE), halogen-free (HF), low smoke emission (LS) or flame retardant (FR).

Ampacity Conditions

  • Ampacity to 90°C conductor temperature, 30°C ambient temperature.
  • Not more than three current carrying conductors in duct or direct burial. NTC 2050, Table 310.15(B)(16).

NOTE:

  • The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
  • Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class B
Insulation
Cross-linked polyethylene
Outer sheath
PVC

Electrical characteristics

Electrical characteristics

Operating voltage
600 V

Mechanical characteristics

Mechanical characteristics

Crush resistance
UL 1277 (NTC 5916)
Mechanical resistance to impacts
UL 1277 (NTC 5916)

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C
RoHS compliant
Yes
Oil resistance
Yes
U.V resistance
Yes
Fire retardant
Method 1 - Vertical Tray (UL 2556/9.6)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close