LOW HALOGEN CABLES LHFR-LS AL S8000 90°C
1/0AWG
Nexans ref. 209785
- Approximate weight: 246.7 kg/km
- Conductor cross-section: 53.5 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 12.71 mm
- Max. DC resistance of the conductor at 20°C: 0.55 Ohm/km
- Perm current rating in duct/buried 30°C: 135 A
2 AWG
Nexans ref. 209783
- Approximate weight: 153.86 kg/km
- Conductor cross-section: 33.6 mm²
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 9.97 mm
- Max. DC resistance of the conductor at 20°C: 0.875 Ohm/km
- Perm current rating in duct/buried 30°C: 100 A
2/0 AWG
Nexans ref. 209786
- Approximate weight: 294.37 kg/km
- Conductor cross-section: 67.4 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 13.73 mm
- Max. DC resistance of the conductor at 20°C: 0.436 Ohm/km
- Perm current rating in duct/buried 30°C: 150 A
250 kcmil
Nexans ref. 209789
- Approximate weight: 521.04 kg/km
- Conductor cross-section: 127 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 18.17 mm
- Max. DC resistance of the conductor at 20°C: 0.232 Ohm/km
- Perm current rating in duct/buried 30°C: 230 A
3/0AWG
Nexans ref. 209787
- Approximate weight: 353.62 kg/km
- Conductor cross-section: 85 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 14.92 mm
- Max. DC resistance of the conductor at 20°C: 0.346 Ohm/km
- Perm current rating in duct/buried 30°C: 175 A
300 kcmil
Nexans ref. 209790
- Approximate weight: 604.23 kg/km
- Conductor cross-section: 152 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 19.44 mm
- Max. DC resistance of the conductor at 20°C: 0.194 Ohm/km
- Perm current rating in duct/buried 30°C: 260 A
350 kcmil
Nexans ref. 209791
- Approximate weight: 686.3 kg/km
- Conductor cross-section: 177 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 20.61 mm
- Max. DC resistance of the conductor at 20°C: 0.166 Ohm/km
- Perm current rating in duct/buried 30°C: 280 A
4 AWG
Nexans ref. 209782
- Approximate weight: 109.07 kg/km
- Conductor cross-section: 21.2 mm²
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 8.57 mm
- Max. DC resistance of the conductor at 20°C: 1.39 Ohm/km
- Perm current rating in duct/buried 30°C: 75 A
4/0 AWG
Nexans ref. 209788
- Approximate weight: 426.78 kg/km
- Conductor cross-section: 107 mm²
- Nominal insulation thickness: 2.03 mm
- Nominal outer diameter: 16.25 mm
- Max. DC resistance of the conductor at 20°C: 0.274 Ohm/km
- Perm current rating in duct/buried 30°C: 205 A
400 kcmil
Nexans ref. 209792
- Approximate weight: 767.47 kg/km
- Conductor cross-section: 203 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 21.7 mm
- Max. DC resistance of the conductor at 20°C: 0.145 Ohm/km
- Perm current rating in duct/buried 30°C: 305 A
500 kcmil
Nexans ref. 209793
- Approximate weight: 927.16 kg/km
- Conductor cross-section: 253 mm²
- Nominal insulation thickness: 2.41 mm
- Nominal outer diameter: 23.65 mm
- Max. DC resistance of the conductor at 20°C: 0.116 Ohm/km
- Perm current rating in duct/buried 30°C: 350 A
6AWG
Nexans ref. 209781
- Approximate weight: 79.15 kg/km
- Conductor cross-section: 13.3 mm²
- Nominal insulation thickness: 1.52 mm
- Nominal outer diameter: 7.45 mm
- Max. DC resistance of the conductor at 20°C: 2.21 Ohm/km
- Perm current rating in duct/buried 30°C: 55 A
Description
Description
Centelsa by Nexans Low-Halogen cables are part of the Nexans Fire Safety offer that allows you to protect people's lives, anticipate risks and secure assets in the event of fires.
Our Low-Halogen Cables do not spread fire, have low smoke emission, do not emit toxic gases and have a maximum operating temperature of 90°C.
Application
Cables for low voltage electrical energy distribution, installations in buildings, inside premises, control panels and electronic circuits. Suitable for places with a high concentration of people, where low-halogen conductors and low smoke emission are required, which in the event of a fire will not generate toxic or corrosive gases that may affect the health of people and the condition of equipment and circuits electronics. The cables can be used for installations mentioned in NTC 2050 Article 310.
LHFR-LS cables have characteristics that make them SUITABLE FOR MEDICAL CARE FACILITIES where invasive procedures are carried out on people, such as surgery rooms, intensive or special care units, etc., since their insulation has very low leakage currents, complying with the provisions of RETIE numeral 28.3.2, literal h.
Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12 AWG gauge and larger.
Note: Any other application or use not described above is considered prohibited.
Construction
Conductor
S8000 Aluminium
Insulation
Low halogen, flame retardant and low smoke emission opaque, dense, toxic and corrosive thermoplastic compound.
Applicable Standars
NTC 6182
Certificate
RETIE N° 07511 / RETIE N° 05915
Operating Temperature
90°C, obtaining greater current capacity compared to a 75°C cable, more efficient electrical design.
Operating Voltage
600 V
Marking
CENTELSA by NEXANS < Calibre AWG / Kcmil > AL AA8000 LHFR-LS 600 V 90°C CT - HECHO EN COLOMBIA [M].
Ampacity Conditions
(*) Current capacity for 90°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit, raceway or directly buried. NTC 2050, Table 310.15(B)(16).
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Fire Safety - NEXANS
LHFR-LS Cables - Low Halogen
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania