HMWPE CABLES Cu 75°C 600V
HMWPE CABLES Cu 75°C 600V
Cathodic Protection Cable is a stranded copper conductor insulated with a black high molecular weight polyethlene (HMWPE) compound.
Read more10 AWG
Nexans ref. 203433
- Conductor shape: Compressed Stranded
- Approximate weight: 96 kg/km
- Conductor cross-section: 5.26 mm²
- Conductor diameter: 2.85 mm
- Nominal outer diameter: 8.59 mm
- Ampacity: 35.0 A
- Max. DC resistance of the conductor at 20°C: 3.41 Ohm/km
12 AWG
Nexans ref. 202053
- Conductor shape: Compressed Stranded
- Approximate weight: 73.71 kg/km
- Conductor cross-section: 3.31 mm²
- Conductor diameter: 2.26 mm
- Nominal outer diameter: 8.0 mm
- Ampacity: 25.0 A
- Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km
2 AWG
Nexans ref. 202056
- Conductor shape: Compact stranded
- Approximate weight: 385.06 kg/km
- Conductor cross-section: 33.6 mm²
- Conductor diameter: 6.81 mm
- Nominal outer diameter: 12.55 mm
- Ampacity: 115.0 A
- Max. DC resistance of the conductor at 20°C: 0.531 Ohm/km
4 AWG
Nexans ref. 202055
- Conductor shape: Compact stranded
- Approximate weight: 261.03 kg/km
- Conductor cross-section: 21.2 mm²
- Conductor diameter: 5.4 mm
- Nominal outer diameter: 11.14 mm
- Ampacity: 85.0 A
- Max. DC resistance of the conductor at 20°C: 0.847 Ohm/km
6 AWG
Nexans ref. 205676
- Conductor shape: Compact stranded
- Approximate weight: 180.92 kg/km
- Conductor cross-section: 13.3 mm²
- Conductor diameter: 4.28 mm
- Nominal outer diameter: 10.02 mm
- Ampacity: 65.0 A
- Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km
8 AWG
Nexans ref. 202054
- Conductor shape: Compact stranded
- Approximate weight: 127.59 kg/km
- Conductor cross-section: 8.37 mm²
- Conductor diameter: 3.39 mm
- Nominal outer diameter: 9.13 mm
- Ampacity: 50.0 A
- Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km
Description
Description
Standards
-
ProductASTM B 3; ASTM B 496; ASTM B 8; ICEA S-95-658; NTC 1099-1
Application
Suitable for direct burial for cathodic protection system for pipelines, storage tanks, pilings, well casings and other buried or water submerged metallic structures.
Note: Any other application or use not described above is considered prohibited.
Construction
Conductor
Class B stranded soft copper.
Insulation
High density, high molecular weight polyethylene, resistant to solar rays (SR), dry and wet sites. Compound free of hazardous substances (RoHS).
Applicable Standards
- ASTM B8
- ASTM B496
- ICEA S-95-658 (NTC 10991-1)
Certificate
RETIE N° 00408
Operating Temperature
75°C
Operating Voltage
600 V
Identification
Insulation in black color.
Ampacity Conditions
- Current capacity for 75°C conductor temperature, 30°C ambient temperature. No more than three current-carrying conductors in a conduit or raceway. NTC 2050, Table 310.15(B)(16).
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania